Generator set series

The G3520H generator set operates on natural gas fuel and is designed for extended-duty combined heat and power (CHP) and continuous electric power applications.

09/25/2014


The G3520H generator set operates on natural gas fuel and is designed for extended-duty combined heat and power (CHP) and continuous electric power applications. Courtesy: CaterpillarCaterpillar's G3520H generator set operates on natural gas fuel and is offered at 2500 kWe power output at 50 and 60 Hz. The G3520H is designed for extended-duty combined heat and power (CHP) and continuous electric power applications like hospitals, data centers, manufacturing plants, greenhouses, and distributed generation power plants. The G3520H also features an open combustion chamber design, which allows use of a low-pressure fuel system (0.5 to 5 psi/ 10 to 35 kPa) that facilitates maximum performance on pipeline natural gas. The major overhaul period of the G3520H is 80,000 hours with an in-frame maintenance interval at 40,000 hours. Other features include a complete gas train, package-mounted air cleaners, and easy wiring connectivity.

Caterpillar

www.caterpillar.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me