Generating Power On Site

Natural-gas-fueled genset is a 1,200-rpm 60-Hz package that delivers 1.6 MW from an electronically controlled, 20-cylinder advanced lean-burn gas engine, coupled with a six-pole synchronous generator. Mechanical efficiency is rated at 43.5%, with fuel consumption at 6,069 BTU/bhp-hr, and NOx emissions at 1.

11/01/2003


Natural-gas-fueled genset is a 1,200-rpm 60-Hz package that delivers 1.6 MW from an electronically controlled, 20-cylinder advanced lean-burn gas engine, coupled with a six-pole synchronous generator. Mechanical efficiency is rated at 43.5%, with fuel consumption at 6,069 BTU/bhp-hr, and NOx emissions at 1.0 g/bhp-hr. (by Caterpillar)

Lean-burn gensets are 1,600/1,400-kW natural-gas-fired models that boast high fuel efficiency and low exhaust emissions. Each unit features a 16-cylinder engine operating at either 1,500 rpm or 1,800 rpm and is designed for extended maintenance intervals. (1400 and 1600 GQKA by Cummins Power Generation)

Bi-fuel engine generators are rated at 300 kW and 375 kW output. These standby models are capable of operating on 90% natural gas and 10% diesel fuel. Both models are to be offered as elements in a modular power system or as twin sets in a single 600-kW or 750-kW package. (by Generac)

Genset provides a 1,500-kW generator in a 20-ft. ISO container. Four-cycle turbocharged diesel engine features liquid drain ports and filters that are quickly accessible for easy maintenance. Fully insulated container uses a reactive temperature control with dual fans, as well as a vertically mounted radiator that is shock- and vibration-isolated. (by MQ Power)

Power center combines service equipment and generator-transfer equipment in the same unit, allowing for easier generator installation in multi-panel applications. Units are installed next to exterior utility meters and can be paired with generators ranging from 5 kW to 30 kW and are available in 12- or 16-circuit configurations. (by Gen/Tran Corp.)

Turbine Generators are designed for steam and gas turbine applications. Specifications include the following: a power rating of 3.5 to 8.5 MW; voltage of up to 15 kV; a weight of 36,000 lbs. (8.5 MW unit); and frequency of 60 Hz or 50 Hz (at 5/6 voltage and kVA), three phase. (by Kato Engineering)

Motor/Generator uses a patented technology to provide the ride-through of a traditional backup system but without batteries. On utility power, the motor drives the generator mechanically. The electrically isolated generator delivers continuous, clean power. During ride-through, inertial energy drives the generator, which delivers constant frequency and regulated voltage, typically 12 seconds at full load. (by Precise Power)





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me