Gearboxes for field-erected cooling towers

SPX Cooling Technologies' Series M Geareducer gearboxes reduce the speed of the electric motor to optimize fan performance.

03/01/2017


SPX Cooling Technologies' Series M Geareducer gearboxes reduce the speed of the electric motor to optimize fan performance. Series M Geareducer gearboxes provide primary support to the fan, anchors it against lateral movement, withstands shock loads at start-up and during speed changes, and minimizes power transmission losses and noise generation. The M series features gears of high strength, case-hardened alloy steel machined to AGMA Quality Class 9 and above. It is designed to fit into cooling towers for easy replacement and has heavy duty double row interstage bearings for 100,000 hours of life or more. To further extend service life, it is fitted with large oil passageways to help maintain lower oil temperatures. The new Geareducer operates without need for oil pumps, oil filters or oil coolers. It runs with two-stage gear reduction for efficient power transmission and the external cooling fins maximize the surface area for cooler operation. 

SPX Cooling Technologies

www.spxcooling.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me