Fuel moisture sensor for biomass plants

Emerson Process Management has integrated a fuel moisture sensor into their Ovation control system to allow continuous monitoring of biomass feedstock for moisture content.

07/01/2013


Emerson Process Management now offers an integrated solution that enables biomass-fuelled power plants to continually monitor feedstock moisture content and adjust the combustion process for better efficiency. The solution, which combines a biomass fuel moisture sensor with Emerson’s Ovation expert control system, can help reduce maintenance costs as well as boost net yearly MWh production.

Biomass fuels vary considerably in their energy content. Fuel that has high moisture content will generate less heat and will have a significant effect on energy recovery in steam generators. The traditional method of controlling the combustion process is by monitoring the flue gases and adjusting the combustion air to give the best efficiency. However, rapidly changing fuel quality and boiler characteristics can make maintaining optimum conditions difficult.

Emerson’s new integrated solution continuously monitors fuel for moisture content as it is being fed into the combustion chamber. The Ovation system uses this data to adjust the combustion air to match the characteristics of the fuel based on the master set-point output (MWe steam or pressure), boiler response and the thermal cycle overall. This enables the plant to react much more quickly to changes in fuel moisture content, maximizing combustion efficiency.

Suitable for new or existing installations, the system comprises a small skid that takes biomass fuel from the transport system, measures its moisture content using microwave technology and returns it to the transport system. 

The moisture sensor is connected via Ethernet to the Ovation system, providing an input to the boiler and thermal-cycle control logic. The data provided is analyzed to provide fast and accurate information on the temperature and moisture content of the feedstock.

Monitoring and controlling combustion air can dramatically influence profits and costs of boiler operations. Excess oxygen does nothing to improve combustion. Instead, it actually serves to reduce boiler efficiency by absorbing heat that could be used in steam production. Ovation helps to modulate the amount of air in the system to provide the exact amount of air that the system needs, ensuring efficient combustion. 

Emerson Process Management

www.emersonprocess.com 

- See more Control Engineering sensor products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me