For machines that cannot be upgraded, what needs to change now that Microsoft Windows XP support has ended?

Ask Control Engineering sought advice from industrial software developers related to the end of Microsoft Windows XP support. Here, Beckhoff Automation provides answers related to Microsoft Windows XP obsolescence.

04/11/2014


 

Ask Control Engineering: For manufacturers that may not be able to upgrade certain machines or systems past Microsoft Windows XP, what should change now that Microsoft Windows XP support has ended? Answers for related questions below are provided by Debra Lee, software specialist, Beckhoff Automation.

Q. What happens to machines using Microsoft Windows XP when Microsoft support ends April 8?


A. Now that support from Microsoft for Windows XP has ended, machines with this operating system (OS) will no longer be able to get OS updates, including security updates. Naturally, best practices dictate that machines be kept up to date with the latest security updates. However, most of these machines are not connected to the Internet, and those that are generally are not used for surfing the Internet nor do they open files or attachments in software applications such as e-mail, both of which are notorious for the spread of viruses and malware. It is important to note as well that many machines are actually running Windows XP Embedded. Support for Windows XP Embedded is still active and does not end until Jan. 12, 2016.

All that said, it is important to fully understand the current situation to learn if and when a corrective action may need to be taken to address the OS on a machine.

Q. What have Beckhoff software engineers been recommending to customers?


A.
It is recommended to assess each machine's individual security risks and take action as appropriate. Every application is different and so too are the potential risks. Simply securing access to a machine can go a long way towards reducing many potential security threats. This extends not only to Internet connectivity, but also to USB devices. Only USB devices that are "verified clean" from authorized personnel should be permitted on the industrial devices that are equipped on machinery. USB flash drives that are used for any personal reason (photos, music, etc.) should never be used on a machine, regardless of the OS used.

Beckhoff is a Microsoft Windows Embedded Gold Partner, and our software experts work closely with Microsoft in the development, implementation, and support of Windows OS products in industrial applications. Gold status is the highest and most exclusive level of the Microsoft partner program. We leverage this relationship in order to better support our customers and provide recommendations for best practices. For our customers, Beckhoff provides detailed "how-to" documentation for securing Beckhoff Industrial PCs (IPCs) and Embedded PCs on our website. This documentation is continuously updated and it provides information to help protect against potential security threats. Link to a Beckhoff Automation security document here.

Q. If customers cannot upgrade, what should change, if anything, on April 9?

A. If a security audit finds that access to the machine is secured and there is no Internet connectivity or e-mail "read" access with file download capability on the machine, nothing necessarily needs to change today even if a machine has devices with Windows XP OS on it. If the security audit finds a potential hazard in these areas, however, action may need to be taken to remove the access points, or if that is not possible for some reason, upgrade the device(s) on the machine. Of course, users should remember that Windows XP Embedded support is still active and will continue to be active until the beginning of 2016.

Q. Will you (or others?) be providing Windows XP patches if vulnerabilities are exposed after April 8?

A. We do not provide security patches for the Windows XP operating system. Microsoft recommends that to stay protected, one should upgrade or replace PCs running Windows XP; however, their perspective is more focused on business and consumer PC users.

Microsoft has a help page on the end of Windows XP support
.

Bottom line: This is not the first OS obsolescence event for industrial device users and it won't be the last. In fact, there are still industrial PCs in the field today running DOS with reliable performance and no problems. Users just need to be cognizant of how their machinery is connected to the outside world, if at all, and how secure the access to these machines is.

- Edited by Mark T. Hoske, content manager, CFE Media, Control Engineering, mhoske@cfemedia.com.

-Control Engineering has a Cyber Security Training Series of Videos.

-See links to related Microsoft Windows XP advice and information below.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me