Flowmeter for filling machines with high precision

New Micro Motion filling transmitter offers Coriolis technology for accurate mass readings.

03/07/2011


New Micro Motion filling transmitter offers Coriolis technology for accurate mass readings.Emerson Process Management has announced a new Micro Motion Filling Mass Transmitter, designed for any process that requires high-speed, high-accuracy filling or dosing. Using its MVD (multivariable digital) technology, Emerson says the Micro Motion Coriolis sensor is well suited for a variety of linear and rotary filling machines across the life sciences, food and beverage, and chemical industries. The unit can handle extremely fast fills (less than one second) and challenging fluids such as those with entrained air, suspended solids, or high viscosity. Integrated valve control reduces external processing and increases accuracy.

Following a trial of Micro Motion meters, Mike Mihalik, VP of engineering at Pneumatic Scale Angelus, said, “The results with Micro Motion Coriolis filling meters showed higher efficiency by improved reliability – 10,000 containers per shift vs. 8,000 with older, less reliable filling technology.”

The Filling Mass Transmitter, like other Micro Motion Coriolis meters, delivers mass, density, and temperature process data in one device, supporting continuous monitoring of product quality with a complete real-time view of fluid characteristics. Digital communications provide continuous monitoring of density and temperature for real-time quality control, and enable changes on the fly to fill target or recipe. 

The automatic overshoot compensation (AOC) feature automatically adjusts valve management to compensate for changes in process conditions such as delivery pressure and fluid characteristics, delivering accuracy and reliability with minimal setup and maintenance. With direct mass measurement and high stability (turndown), the Filling Mass Transmitter is suitable for filling a variety of container sizes and products with a single sensor

The unit is compact and light, minimizing space requirements and reducing installation cost and effort. Easy to integrate into almost any filling machine, the slim profile and compact dimensions reduce the footprint and allow for the maximum number of fill heads. The Filling Mass Transmitter is compatible with the Micro Motion F-Series and H-Series ranges of Coriolis sensors, and also with the Elite sensor for very small fills. Simply select the sensor size and surface finish, and choose Modbus or Profibus-DP digital communications, integrated valve control for speed and reliability, or a frequency/pulse output for traditional pulse-counting applications.

The filling meter has no moving parts, the electronics are immune to temperature shocks from CIP/SIP procedures, and the sensors feature a hygienic drainable design. They are 3A-authorized, EHEDG certified for hygienic use, and designed for fast and easy cleaning.

www.EmersonProcess.com

Visit the Control Engineering Process Control Channel

Edited by Peter Welander, pwelander@cfemedia.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me