Flow computer handles critical oil mass and volume calculations

New meter prover interface feature from ProSoft Technology performs sophisticated functions on Rockwell’s ControlLogix platform.

04/29/2011


New meter prover interface feature from ProSoft Technology performs sophisticated functions on Rockwell’s ControlLogix platform.ProSoft Technology has announced version 2.07 of its Liquid and Gas Flow Computer for the Rockwell Automation ControlLogix platform (MVI56-AFC). In oil applications, crude is extracted and transported through pipelines that often run hundreds of miles through varying climates, temperatures, and altitudes. As these elements vary, so do the properties of the petroleum, necessitating flow computers to validate the precise quantity of product at designated points along the pipeline. Precise flow calculations require accurate data from properly calibrated flow meters. Meter provers help validate proper flow meter operation.

The ProSoft Technology flow computer calculates a meter factor based on constants and variables affecting flow rates, accumulated volumes, and accumulated mass of the liquid petroleum product flowing through a prover with known volume. With the new meter-proving feature, the module is now able to communicate meter-prover test results directly to the control processor and SCADA control system. Operation of the prover-interface feature can be performed manually, completely automated, scheduled, triggered by events, or operator intervention.

The prover interface feature supports these prover types:

• Unidirectional pipe prover;
• Bidirectional pipe prover;
• Compact prover; and
• Master meter prover.

The module resides directly in the ControlLogix chassis, acting as an add-on co-processor, dedicated to calculating flow measurements without burdening the PLC with complicated flow algorithms. Additional features include:

• Multiple, independently-configuratble meter streams: The module supports up to 16 meter runs with four streams per meter and allows the PLC/PAC to switch the active stream via program logic. Each of the channels are individually configurable to calculate hydrocarbon gas or liquid flows.

• High precision analysis for multiple streams: Fractional components of hydrocarbon gases may be entered as floating-point values with precision of seven or more significant digits.

• Completely automated control: The module is programmed, managed, and monitored by the PLC or SCADA system.

• Complies with AGA 3, 7, 8, and MPMS Chapters 11 and 12.2 measurement standards.

• Event log lockout security: Prevents overwriting past events which have not yet been downloaded and archived in some off-module system.

• Modbus dictionary: This index allows users to locate the Modbus address of needed data.

www.prosoft-technology.com

Visit the Control Engineering Process Control channel.

Edited by Peter Welander, pwelander@cfemedia.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me