Fire and life safety: Integration: Building automation systems and fire/life safety

Like a BAS, fire protection and alarm systems have also evolved into sophisticated computer-based systems, which offers more opportunities to integrate these systems to develop a more complete building response as part of overall building operations during an emergency event.

09/10/2014


Integrating fire protection and fire alarm systems with building automation systems (BAS) can offer efficient and cost-effective operation. The design and installation of an integrated system must also be well-planned and coordinated, and the system must be properly maintained over its lifetime. The need for multidisciplinary coordination between the fire protection engineer and the mechanical and electrical engineers during design and construction are of key importance. Design engineers also must involve the building owner and/or operator in establishing (or at least influencing) the design criteria of the building. The owner/operator must understand that the efficiencies gained by integration will pay dividends long into the lifecycle of the building.Like a BAS, fire protection and alarm systems have also evolved into sophisticated computer-based systems, which offers more opportunities to integrate these systems to develop a more complete building response as part of overall building operations during an emergency event.

Learning objectives:

  • The audience will understand the provisions of NFPA codes/standards, International Building Code, and International Fire Code applicable to BAS integration.
  • Viewers will learn the criteria for ensuring interoperability of an integrated system.
  • The audience will understand the advantages and disadvantages of integrating fire protection and fire alarm systems with BASs.
  • Viewers will understand the applicable communication protocols, such as BACnet and LonWorks.

Presenters:

Erik Anderson, PE, Manager, Koffel Associates, Columbia, Md.

Wayne D. Moore, PE, CFPS, SET, FSFPE, F.NSPE, Principal and Vice President, Hughes Associates | RJA Group, Warwick, R.I.

Moderator: Jack Smith, Consulting-Specifying Engineer, Pure Power, and CFE Media, LLC



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me