Fire alarm detection system

The Advanced Signal Analysis (ASA) by Siemens provides reliable and false alarm resistant fire detection.

08/09/2012


Advanced Signal Analysis (ASA) by Siemens Building Technologies Division provides reliable and false alarm resistant fire detection for a wide range of applications. Siemens’ ASA technology is a software-based solution that in real time, dynamically compares sensor signal data to sophisticated algorithms to accurately and reliably differentiate between a fire emergency and harmless smoke, steam, or dust. Siemens multi-criteria fire detectors integrate five sensors (including two optical for forward/backward scattering, two thermal, and one CO, depending on model) in a single detector. Through ASA, fire detectors quickly process the sensor array’s signals to determine alarm or monitoring status. Siemens fire detectors provide for the earliest detection of smoke, heat, and CO in any environment. Siemens ASA detectors are certified as life-safety CO gas detectors meeting NFPA 720 and UL 2075. They also feature 26 user-friendly selectable detection profiles, nine field-selectable temperature settings, and their high sensitivity meets NFPA 76 Very Early Warning Fire Detector criteria. 

Siemens Industry Inc.

www.siemens.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me