Fieldbus network diagnostic module gets DTM update

P+F ADM observes behavior of a segment, uses intelligence to diagnose situations based on past experience.

11/05/2010


Pepperl+Fuchs has introduced the newest version of its Advanced Diagnostic Module (ADM) DTM software. ADMs monitor the quality of fieldbus communication for Foundation fieldbus H1 and Profibus PA networks, and the Diagnostic Manager software includes a number of updates that dramatically speed fieldbus commissioning and take the guesswork out of troubleshooting for ADM users. This smart software tool translates information provided by the ADM into actionable information and can run on a server located directly in the control room. P+F says this turns the complete fieldbus infrastructure into an open book that can be read without expert knowledge. 

“The most significant improvement to the new Diagnostic Manager is a built-in expert system that automatically learns the communications behavior of a segment during commissioning,” says Brian Traczyk, product manager, Pepperl+Fuchs.  “Over time it is able to intelligently diagnose any situation on the basis of past experience. As a result, users are provided with specific warnings as soon as the software detects any condition that might lead to a critical situation.  Such warnings are complemented by incident-related information in clear text that points to possible causes and recommends remedies.”

Traczyk adds that when field technicians are equipped with this information, they usually know what needs to be done before they arrive on site, and are no longer faced with the sometimes time-consuming task of searching for the actual cause of a problem. As a result, time spent on troubleshooting is absolutely minimized, plant shutdowns can largely be avoided, and the availability of the complete system is considerably improved.

Additional upgrades include automated tag reading in combination with a fieldbus host, and improved oscilloscope functions.

www.pepperl-fuchs.us

- Edited by Peter Welander, pwelander@cfemedia.com

Also read: Fieldbus Foundation updated technical spec supports fieldbus devices, diagnostics

Visit the Control Engineering Process Control Channel.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me