Explosion-proof smoke detectors

The Det-Tronics SmokeWatch is applicable to industrial HVAC duct-monitoring.

08/27/2017


The unit's photoelectric sensor ensures accurate smoke detection with less potential for false alarms than other smoke detection technologies. Courtesy: Det-Tronics

The Det-Tronics SmokeWatch U5015 uses advanced photoelectric smoke detection technology not generally available in an explosion-proof housing. The detector is rated for Class 1 Division 1, 2 and Zone 1 environments found in industrial applications. Used with the Q5016 Duct Mount Accessory, the detector can be installed on ductwork to meet NFPA 90A requirements for air handler units of more than 2,000 cfm.

The unit's photoelectric sensor ensures accurate smoke detection with less potential for false alarms than other smoke detection technologies. The detector's design operates effectively in both smoldering and rapidly growing fires.

Approved for both HVAC ductwork and area installation, the SmokeWatch U5015 unit integrates with fire alarm systems for evacuation alerts. When connected to process controls, the SmokeWatch U5015 can be used to initiate smoke-control procedures such as fan shutdown and fire damper operation. The detector carries FM 3230 approval for detection performance and meets NFPA 72 and 92 equipment requirements.

Det-Tronics

www.det-tronics.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me