Exploring the high demands for higher education facilities: sustainable buildings/energy efficiency

The design process for higher education facilities has its own set of challenges and requirements. Engineers discuss the current trends, challenges, and experiences with college and university facility projects regarding sustainable buildings/energy efficiency.

10/28/2016


Mark Fisher, PE, LEED AP, Principal, AlfaTech, San Jose, Calif. Scott Foster, PE, LEED AP, Principal, Affiliated Engineers Inc., Chicago Keith Hammelman, PE, Senior Vice President, CannonDesign, Chicago
Tom Hickey, PE, Plant and Building Services Market Leader, Stanley Consultants, Muscatine, Iowa James Newman, PE, CEM, BEMP, LEED AP BD+C, High Performance Design Team, Leader, EYP Architecture & Engineering, Boston Jose I. Torres, PE, MBA, Project Manager/Mechanical Engineer, RMF Engineering Inc., Raleigh, N.C.

Respondents

Mark Fisher, PE, LEED AP, Principal, AlfaTech, San Jose, Calif.

Scott Foster, PE, LEED AP, Principal, Affiliated Engineers Inc., Chicago

Keith Hammelman, PE, Senior Vice President, CannonDesign, Chicago

Tom Hickey, PE, Plant and Building Services Market Leader, Stanley Consultants, Muscatine, Iowa

James Newman, PE, CEM, BEMP, LEED AP BD+C, High Performance Design Team, Leader, EYP Architecture & Engineering, Boston

Jose I. Torres, PE, MBA, Project Manager/Mechanical Engineer, RMF Engineering Inc., Raleigh, N.C.


The design process for higher education facilities has its own set of challenges and requirements. Engineers discuss the current trends, challenges, and experiences with college and university facility projects regarding sustainable buildings/energy efficCSE: Energy efficiency and sustainability are often requested by building owners and CIOs. What net zero energy and/or high-performance systems have you recently specified on college/university projects? 

Foster: We’ve specified radiant ceilings and panels, in-slab radiant cooling, geothermal fields (dedicated and campuswide), solar panel installations, variable-volume fume hoods, heat-recovery chillers, and chilled beams.

Hammelman: In a recent net zero energy project for Ohlone Community College, we specified the use of a reversible chiller connected to a geothermal borefield. This was needed to obtain the energy efficiency of the central utility plant and achieve the energy-use intensity at a level to be offset by the onsite PV-generation system. The chillers were configured in a way to properly produce the necessary heating and cooling water for the campus simultaneously. This system in combination with the use of LED lighting, integrated lighting controls, and an energy-efficient envelope allowed for this facility to be a net zero energy project.

Newman: The two primary areas of focus for designing a high-performance HVAC system to mitigate the peak-energy end use for science/laboratory buildings is high-efficiency heat recovery and occupancy/operational lab space controls for reduced flows. Specifying a high-efficiency run-around loop heat-recovery system for science/laboratory building applications allows for peak amounts of heat recovery while still meeting the requirement for keeping supply and exhaust airstreams separated. Designing the lab spaces with occupancy/operational lab space controls can allow for reduced airflows during periods of room vacancy. For this energy-intensive building type, a sustainable HVAC system can be achieved with the two-pronged approach of, first, recovering as much energy as possible from the exhaust air during normal operation and, second, constantly looking to reduce the amount of outdoor ventilation air delivered to the building whenever possible.

Fisher: We have designed PV systems, fuel cells, and solar hot-water systems. We have also designed state-of-the-art HVAC systems with variable refrigerant, chilled beams, and geothermal heat pumps for various colleges and universities. Our lighting staff was involved in a study to determine the most energy-efficient lighting solution for parking lots at University of California, Los Angeles, and the solution was implemented throughout the entire campus. We routinely specify transformers whose efficiencies exceed the Department of Energy’s 2016 requirements. We have found a 15% reduction in lighting energy by specifying lighting control systems with every lighting fixture independently controlled.


<< First < Previous Page 1 Page 2 Next > Last >>

Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me