Exploring robotics for the factory of the future

Control Engineering Europe’s Suzanne Gill reports on a European Commission co-funded project that is testing the idea that industrial robot technology could provide a good base for machining, being both flexible and cost-efficient. Researchers are engineering robots to perform CNC operations.

12/30/2011


The European Commission is co-funding an €8 million project as part of the European Economic Recovery Plan (EERP) adopted in 2008, which targets the use of industrial robots for high-end machining for cost-effective, flexible, and reliable manufacturing solutions for the “Factory of the Future.”

COMET project test execution: machining of the aluminum workpiece for a different robot configuration (DOE ½ Factorial Plan, 6 factors, 2 levels). Courtesy: COMET

The inaugural meeting of the European project was hosted in Spain in September 2010 by the coordinating partner of the project, Delcam. The COMET project sees 14 companies from industry, research institutes, and universities sharing and combining their manufacturing expertise with the aim of developing plug-and-produce COmponents and METhods for adaptive control of industrial robots for high-end machining to enable cost-effective, flexible, and reliable manufacturing solutions.

Mark Gadsden, product marketing manager at Delcam, explained more about the aims of the project: “The 30-month COMET project aims to overcome the challenges facing European manufacturing industries by developing innovative machining systems that are flexible, reliable, and predictable with an average of 30% cost-efficiency savings in comparison to machine tools.”

Because it is both flexible and cost-efficient, industrial robot technology could, from a conceptual point of view, provide a good base for machining. However, in real-life situations industrial robots have three critical limitations: a lack of absolute positioning accuracy, an inability to reject disturbances in terms of process forces, and a lack of reliable programming and simulation tools to ensure right-first-time machining when production commences. At the present time these limitations are preventing the use of robots in typical machining applications.

Four elements

The COMET project consists of four elements that, together, aim to overcome these limitations. These include:

1. A methodology for describing kinematic and dynamic models of industrial robots (KDMIR) to define accurately the static and dynamic behavior of any industrial robot, which then is represented by its unique signature.

2. An integrated programming and simulation environment for adaptive robot path generation for machining with industrial robots (PSIR), based upon the unique signatures.

3. An adaptive tracking system for industrial robots (ATIR) to detect deviations from the programmed robot path and to adaptively initiate real-time corrections via the robot controller to ensure the necessary machining accuracy.

4. A high dynamics compensation mechanism (HDCM) to accomplish an absolute accuracy better than 50 μm; significantly “beyond” the structural capability of the robot system on its own.

Noble aims indeed, but the project has some interesting challenges to overcome, as COMET partner TEKS points out. Robots are a compromise between a comparatively low dynamic accuracy, and unrivalled handling flexibility. This means that, while robots are very agile, this agility results in a reduced stiffness compared to conventional machine tools.

The TEKS robot cell is based at the Advanced Manufacturing Park (AMP) in Rotherham. The company, which has already co-hosted one of the regular general assembly meetings of the project, was the first with an operational cell to begin undertaking trials for COMET.

TEKS is in the process of developing its robotic cell and with consortium partner, Artis of Germany, it has conducted force measurement tests while machining aluminium. The forces generated by the cutting operation have been recorded in detail with an Artis prototype data acquisition solution, at a high sampling rate of 500 kHz.

Roland Krain, research and development manager at TEKS, explained the potential benefits of this approach: “Traditionally robots are used as handling solutions for assembly. If machining is required in a robotic line or cell, the robot typically would place the part in a conventional machine tool. Such tools range from the high tens of thousands pounds to several hundred thousand pounds. A robotic machining cell could provide a cost-effective machining solution. A secondhand robot can, typically, be purchased for £15k, along with a good quality high-speed spindle for £20k, giving the end user multi-axis machining capability for a fraction of the cost of a comparable conventional machine tool. Obviously the secondhand robot has to be in ‘as new’ condition, be well maintained, and have a compatible controller; otherwise, the accuracy required might not be achieved.”

“Today, customers generally opt for either a 5-axis machine or a handling robot. If we could bring the two things together, we would be able to make customers more productive and more competitive,” concludes Krain.

Setting up cells

Robot cells have now also been set up at a variety of partner facilities using robots from manufacturers such as Kuka, ABB, Motoman, and Comau. The cells will enable industrial tests to be performed on a range of parts, ensuring that all developments take into consideration the acceptability to end users in terms of time, cost, and reliability. Commenting on the COMET project to date, Dr. Ir. Jan Ramboer, research programme officer from the European Commission, said: “The COMET project is an ambitious and innovative project. I am pleased to see robots being used early on to perform physical tests which are relevant to applications in the European manufacturing industry. Everything is very clear and there is an excellent synergy between partners. Dissemination is good across all levels, in particular the use of social media for communicating the project objectives and developments.”

COMET project YouTube videos include these and several more, showing how robotics and machining combine. www.youtube.com/user/COMETproject  Courtesy: COMET, YouTube

Over the next six months almost all the technical tasks in the project will be active. To enable partners to plan and conduct robot machining experiments, a prototype of the high dynamics compensation mechanism (HDCM) will be available. The HDCM will help to accomplish an absolute accuracy better than 50μm—significantly beyond the structural capability of the robot system on its own. The integration of models together with the PSIR, ATIR, and HDCM will ensure that tests are performed in realistic end-user environments.

Jan Willem Gunnink from Delcam, coordinator of the project, said: “I have complete confidence that European manufacturing organizations will benefit from the combined knowledge of the COMET partners, which comes from industry, research institutes, and universities. Since the inaugural meeting in September 2010, partners have demonstrated their ability to work as a team, providing a good foundation for the COMET project to move forward and develop new and exciting robot technologies in 2011.”

Klas Nilsson, associate professor from COMET partner, the University of Lund in Sweden, also believes that the project will have major benefits. He said: “This type of project, where you bring together competencies from across Europe, will find new problems too! Together we are able to complement each other to find the best solutions to these problems.”

John Pandremenos from the University of Patras in Greece and dissemination manager of the project, said: “If the project achieves its objectives it will bring big innovations to the manufacturing sector in European industry. It will significantly reduce the cost of machining operations.”

A video about the project can also be viewed at www.youtube.com/user/COMETproject, or visit the project website at www.comet-project.eu.

- Suzanne Gill is editor of Control Engineering Europe. This article appeared originally appeared at www.controlengeurope.com and was edited for the Control Engineering International pages in the January 2012 North American edition of Control Engineering.

 

www.controlengeurope.com/article/43246/Exploring-robotics-for-the-factory-of-the-future.aspx



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me