Exhaust Grilles in Anesthetizing Locations

Some jurisdictions have state health regulations that require smoke-exhaust grilles in the ceiling of an anesthetizing location. Isolation dampers are required to isolate the return duct from the exhaust duct. Either a return/relief fan or a separate exhaust fan could be used to remove smoke.However, preliminary testing of this approach has produced mixed results.

01/01/2001


Some jurisdictions have state health regulations that require smoke-exhaust grilles in the ceiling of an anesthetizing location. Isolation dampers are required to isolate the return duct from the exhaust duct. Either a return/relief fan or a separate exhaust fan could be used to remove smoke.

However, preliminary testing of this approach has produced mixed results. With the low air velocity exiting the laminar-flow air devices, the exhaust-air pattern has been shown in cold smoke tests to short circuit and leave a lower level of smoke-table height and below-within the room. Warm smoke may have a better chance of being drawn out at the ceiling level, but the short-circuit possibility still exists. Smoke generated at the table level from surgical drape fires might be drawn across the staff on its way to the ceiling exhaust or left at the lower level.

This removal concept matches the smoke-management techniques applied to atriums and other spaces, where the smoke is directed upwards and the lower six feet of egress space is maintained clear of smoke. The main difference is that in atriums supply air is introduced at the lower level during smoke-removal scenarios while air is supplied at the ceiling in operating rooms at all times.

Further testing is required to ensure proper and safe smoke removal using the typical ceiling-exhaust technique.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me