Ethernet switches have PoE Plus for higher power devices

Belden MACH104-16TX-PoEP Ethernet switches with Power over Ethernet Plus (PoE Plus) capability (the IEEE 802.3at standard) delivers increased power for Ethernet-enabled devices.

08/03/2011


Belden (NYSE:BDC) introduced the MACH104-16TX-PoEP Ethernet switches with Power over Ethernet Plus (PoE Plus) capability in accordance with IEEE 802.3at standards. (The PoE+ standard allows higher power to go through the Ethernet cable, up to 25.5 W.)

Belden Mach104-16TX-PoEP Ethernet switches with Power over Ethernet Plus (PoE Plus) capability, in accordance with IEEE 802.3at standards. (The PoE+ standard allows higher power to go through the Ethernet cable, up to 25.5 W.) Courtesy: Belden

As new technologies evolve and a new breed of Ethernet enabled devices, such as IP cameras, VoIP phones, and video conferencing come on the market, the need for increased power and speed over Ethernet networks is of paramount significance.

The MACH104-16TX-PoEP series of hardened Ethernet workgroup switches are managed all-Gigabit switches with sixteen Gigabit PoE/PoE+ ports and four additional Gigabit RJ45/SFP combo ports. A version with two additional 10 Gigabit XFP ports is also available to facilitate high bandwidth backbone requirements. Power options include a choice of single/dual 110/220 V ac inputs or external 48 V dc external inputs for fanless operation (0 degrees C to + 50 degrees C). Each chassis, measures 448 mm x 44 mm x 345 mm, and can be mounted in a 19-in. cabinet.

The switch’s management functionality reportedly facilitates media redundancy systems such as Hiper ring, MRP (IEC ring function) and rapid spanning tree to ensure a high level of network availability. The extensive security mechanisms provided include multi-client authentication via Radius server, access control via IEEE 802.1x or MAB (MAC Authentication Bypass), IP and MAC port security plus SNMP V3 and SSH. True SNMP functionality allows use of centralized management software - such as Industrial HiVision – for commissioning, remote management, diagnostics and troubleshooting.

Each switch apparently comes with an integrated V.24 and USB interface. The V.24 interface is an RJ11 socket for optional (local) serial configuration, while the USB socket can be coupled with an ACA 21 adaptor (sold separately) to store the configuration data, recall it as necessary, and apparently upgrade or downgrade the operating software automatically, bringing potential downtime to an absolute minimum.

- Edited by Chris Vavra, Control Engineering, www.controleng.com

http://www.controleng.com/new-products/industrial-networks.html



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me