Ethernet box offers analog inputs, outputs on one device

Machine-mountable Beckhoff Automation EP4374 EtherCAT combination I/O box enhances machine design flexibility, with two analog inputs and two analog outputs in one device.

05/28/2011


Beckhoff Automation has reportedly extended its range of IP67 I/O modules with the new EP4374 EtherCAT Box. This flexible, moisture and dust-resistant I/O device combines two analog inputs and two analog outputs into one device. 

The versatile EP4374 I/O box is a reportedly finely scalable EtherCAT solution that empowers machine builders to plan ahead based on demand and, therefore design more cost-effectively. The input and output channels can be parameterized independent of each other for the standard signals 0-10 V, ±10 V, 0-20 mA and 4-20 mA.

With the combination of parameterizable inputs and outputs in a single rugged housing, EP4374 users benefit from increased flexibility and can utilize the existing signals in an optimized manner. This new EtherCAT Box features two input channels and two output channels. Each channel is configurable individually for current or voltage measurement or output. The resolution for the current and voltage signals is 16 bit (signed).

The EP4374-0002 module reportedly has a direct EtherCAT connection, so that the high performance of 100 Mbit/s Industrial Ethernet is retained right down to each IP67 box. The compact dimensions of the EtherCAT Box of only 126 x 30 x 26.5 mm (H x W x D) make it ideal for applications in confined spaces.

For more information:

EP4374 EtherCAT Box

Industrial network news, trends, products, articles: www.controleng.com/networks.

- Edited by Chris Vavra, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me