Estimated Annual Global Market for Industrial Solar Roofs Exceeds $100 Billion

01/26/2006


Solar Integrated Technologies , Los Angeles, announced recently that it completed 39 industrial solar roofing projects in 2005, bringing the company’s total installed projects to 58 aggregating more than 5 MW of installed generating capacity. These projects, installed in Arizona, California, Nevada, New York, Texas, Germany and Spain, represent a range of industries and customers, including Coca-Cola, Frito-Lay, Honeywell, ProLogis, San Diego City Schools and Wal-Mart.

“The significant increase in our install base of customer sites in 2005 is very exciting.ssable market for industrial solar roofs exceeds $100 billion, based on current market estimates for non-residential roofing.”

Until the recent introduction of Solar Integrated’s commercial BIPV roofing products, the application of solar panels for large area low-slope roofs was limited due to the weight of traditional rigid crystalline solar panels and the roof penetrations required to secure these heavy panels. To address these building limitations, Solar Integrated developed an innovative BIPV roofing product that combines lightweight roofing material with flexible solar panels. Solar Integrated’s unique solar roof panel weighs only 12 oz per square foot and lies flat on existing roof top facilities without exceeding roof loading limitations. By comparison, traditional crystalline solar panels weigh 8 lbs per square foot and often require roof modifications before installation.

In addition, unlike 94% of other solar technologies, the Solar Integrated amorphous BIPV product does not use purified silicon as a raw ingredient, but rather uses silane gas, which requires only trace amounts of silicon. Therefore, Solar Integrated’s amorphous BIPV products are not constrained by global silicon supply and pricing. These key product characteristics are enabling the Company to unlock the potential of industrial roofing as a nascent market for on-site solar power generation.“

By creating a viable solar roofing solution for “big box” industrial buildings, our customers have the potential to generate on-site renewable power, while simultaneously reducing peak energy demands on the grid and reducing dependence on fossil fuel-based energy production,” continued Mr. Slangerup. “For example, by the year 2010, California is projected to have approximately 3.6 billion square feet of low slope industrial roof space. If this space was used to host our BIPV solution, California’s industrial roof tops could generate 9 GW of renewable power, equal to about 15% of the State’s peak electricity demand. Extrapolating this over the world’s available industrial roofing real estate creates an extraordinary renewable energy opportunity.”



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me