Environmentally friendly cables

EcoCable and EcoFlex by Alpha Wire are nonhalogenic and meet RoHS and WEEE requirements. They are designed to be lighter and smaller than traditional PVC cable and can be used in extreme temperatures.

01/18/2013


EcoCable and EcoFlex by Alpha Wire are nonhalogenic and meet RoHS and WEEE requirements. They are designed to be lighter and smaller than traditional PVC cable and can be used in extreme temperatures. Courtesy: Alpha WireAlpha Wire's EcoCable and EcoFlex are designed to be up to 65% lighter and 47% smaller, with up to 91% lower outgassing than traditional PVC cable. The two control cables are nonhalogenic and contain no heavy metal pigments, allowing them to meet RoHS and Waste Electrical and Electronic Equipment (WEEE) requirements.

EcoCable offers space savings of up to 47% compared to traditional PVC control cable. For example, a 22 AWG PVC insulated cable has a diameter of 0.502 inches (12.75mm). The equivalent EcoCable has a diameter of 0.219 inches (5.56mm). Its counterpart EcoFlex offers space savings of up to 32% versus PVC and is rated for up to 1 million flex cycles. 

The initial EcoCable offering is a UL AWM 21510 and CSA Rated cable available in sizes ranging from 24 AWG (0.28 mm²) to 14 AWG (2.08 mm²) available in 100 ft and 1000 ft lengths. EcoCable is suitable for use in NFPA79 applications and is RoHS and REACH Compliant. Its temperature range of -50C to +105C exceeds that of standard PVC cable. 

EcoFlex is a UL AWM 21819 and CSA Rated flexible control cable available in sizes ranging from 28 AWG (0.09 mm²) to 10 AWG (5.32 mm²). It’s offered in 100ft and 1000ft lengths, with bulk available for larger quantities. With up to an 8x flexing bend radius and rated for up to 1 million flex cycles, EcoFlex is suitable for use in NFPA 79 applications and is RoHS and REACH Compliant. Its temperature range  is -40C to +105C static, and -5C to +105C while flexing.

Alpha Wire

www.alphawire.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me