EntelliGuard TU Trip Unit Conversion/Upgrade Kits

07/02/2010


GE has develop its new EntelliGuard TU Trip Unit Conversion/Upgrade Kits, ideal for electrical service organizations, contractors, and industrial end users concerned with improving arc flash protection without sacrificing system reliability, while maintaining and extending the life of an electrical power system.

The product includes both a Waveform Recognition Instantaneous Algorithm and Zone Selective Interlocking Instantaneous, which together can achieve HRC2 or better without sacrificing selectivity for available fault currents as high as 100kA. Other options include a feature called Reduced Energy Let Through (RELT) that provides enhanced arc flash protection during maintenance.

Available to install on legacy GE breakers such as AK, AKR, Power Break, and WavePro series low voltage circuit breakers, the new kits extend the offering to non-GE manufactured breakers including Allis Chalmers, I-T-E, and Westinghouse, while providing all the hardware needed for options like RELT in one easy to install kit.

GE’s EntelliGuard TU Trip Unit Conversion/Upgrade Kits offer: 

  • Flexible time current settings and curves (Including Fuse Shapes)

  • Zone Selective Interlock – GF, S, and I

  • RELT – Reduced Energy Let Through

  • Ground Fault Alarm via I/O or Modbus Communications

  • Easy upgrades to Power Management Control Systems (PMCS) via open Modbus   RTU protocol

  • Large LCD to centrally display three phases on one screen

  • 10 Event log with date and time stamp

  •  Health status via breaker LED indicating normal operation, errors, pickup, and trips while providing non-volatile memory with a continuous self-testing microprocessor

  • Free set-up software that let facilitators easily program all units offline and analyze captured waveforms

  • Full-function metering and relaying; including Waveform capture to enable harmonic analysis four cycles prior and after event

  • Thermal Memory

  • Lithium battery to eliminate need for external power

www.geelectrical.com/industrial



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me