Engineering workable, successful office space: Electric, power systems

Whether new or retrofit, office buildings can be a challenge for the mechanical, electrical, plumbing (MEP), or fire protection engineer. Electrical and power systems are key to these facilities, which includes lighting.

10/23/2014


Julianne Laue, PE, LEED AP, BEMP Senior MEP Engineer, Center for Sustainable Energy Mortenson Construction MinneapolisTony McGuire, PE, FASHRAE Founder McGuire Engineers Inc. ChicagoTony McGuire, PE, FASHRAE Founder McGuire Engineers Inc. Chicago

Respondents

  • Julianne Laue, PE, LEED AP, BEMP, Senior MEP Engineer, Center for Sustainable Energy Mortenson Construction, Minneapolis
  • Tony McGuire, PE, FASHRAE, Founder, McGuire Engineers Inc., Chicago
  • Nathan Snydacker, PE, LEED AP, Vice President, ESD Global, Chicago

Hillshire Brands wanted an open space with a loft-type design to physically manifest a cultural emphasis on collaboration; the company turned to the engineers at ESD Global to help execute the building project. Courtesy: Michelle LitvinCSE: Describe some recent electrical/power system challenges you encountered when designing a new building or working in an existing building. 

McGuire: We are seeing more requirements to provide standby power for data processing systems.

Snydacker: We have encountered capacity to support densification, and arc flash. 

CSE: What low- and medium-voltage power challenges have you overcome? 

McGuire: Clean power is important in many instances, but that has been readily handled from experience. The biggest problem is getting complete information from clients’ IT staff.

CSE: What types of renewable energy systems have you recently specified in one of these projects? This may include photovoltaics, geothermal systems, wind turbines, etc.

Snydacker: We are currently working on a project for Chicago Botanic Gardens that is implementing several renewable energy systems. The design currently includes the use of a lake source geothermal system using surface water as a heat sink during the warmer months of the year. Photovoltaic (PV) panels will be installed on the roof that will produce up to 24 kWh of energy annually (or 7% of the facility's energy consumption). 

McGuire: We used both photovoltaics and wind power in our recent LEED Platinum project. Grey water from the “green roof” was also used.

CSE: What unique lighting and daylighting requests have you fulfilled in recent office projects? 

McGuire: Unique lighting is becoming “ordinary” lighting as is daylighting. Our 18,000-sq-ft office uses less than 0.30 W/sq ft in the space, which is LEED Platinum itself. Lighting controls are extensive.

Snydacker: Perhaps not unique, but oftentimes a request for simplicity can provide a tremendous challenge when it comes to lighting controls. Code requirements for zoning, daylight harvesting, and automation, coupled with all of the products on the market offering integrated audio visual controls, networking, addressable ballasts, etc., can make it very difficult to develop a solution that is elegantly simple and intuitive to use for anyone stepping foot into the new office space. We have helped several of our clients “tone down” their lighting controls either installed by integrators or proposed by lighting consultants to achieve intuitiveness while meeting code requirements for energy efficiency.

re one example that we have seen a number of times.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me