Engineering and IT Insight: virtualize now, send the message to your vendors

Virtualization simplifies system upgrades, and there are at least two more reasons to virtualize and three major issues to address.

06/20/2011


Dennis BrandlVirtualization can simplify system upgrades, and that is a major reason to virtualize. Additional reasons and issues include cost reduction, additional uptime, unique peripherals, industrial networks, and vendor support.

The first Tuesday of every month is a significant date for most IT departments, the day that Microsoft releases patches. On the first Wednesday of each month an army of IT workers at vendor companies start testing the patches on their installed systems and applications. With luck and no compatibility problems, the vendors release advice to their customers about the patches. Meanwhile, end-user companies start performing tests on their systems and applications before they roll out the patches to their production systems. A major problem with this model is the requirement to keep exact copies of production systems available for the patch testing. When changes or updates are made to the production systems, the same changes must be identically applied to the patch test systems. This doubles the hardware cost of a system and doubles the maintenance costs.

Virtualization simplifies this through the use of snapshots. Snapshots are an exact copy of a system’s memory, databases, and installed applications. A snapshot can be loaded on a virtual machine (VM) to give you an exact copy to use in patch testing. There are two common methods to use: snapshot as rollback/backup and snapshot as test copy. The rollback/backup model is used when short-term unavailability of a system is acceptable. A snapshot is taken of the production systems before the patch is installed, the patch is installed, the system is restarted, if necessary, and then it is quickly tested. If no problems occur, then production continues with the patched system. If problems occur, then the system is rolled back to the snapshot.

Snapshot patch testing

The “snapshot as test copy” method is used when production system downtime is not acceptable and a patch reboot is not needed. A snapshot is taken of the production system and then installed in a test VM environment. The patch is applied to the test environment and tested. If the patched system passes the acceptance tests, then the patch is applied to the production system.

Another advantage of visualization is the ability to move a VM from one host server to a new host server without shutting down the VM. This functionality provides a method to upgrade hardware without shutting down applications and impacting production. This also provides a method to increase the CPU power available to an application on an on-demand basis. Not all hypervisor VM systems provide this functionality, so it is important to see what your virtualization system provides. It is also important to test this feature prior to implementing it in production because not all hypervisors handle the switchover in the same manner.

3 virtualization issues to watch

There are three issues in using VMs in manufacturing IT systems: unique peripherals, industrial networks, and vendor support. VM systems have two unique characteristics: all communication must be through an Ethernet network connection, and no special devices can be used. This means that most USB devices, printers, and license dongles must be connected through Ethernet. Also, industrial networks must be connected through Ethernet, special video cards cannot be used, and special keyboards cannot be used. Some virtualization servers will allow you to dedicate a USB port or communication port to a VM, but then the ability to move the VM to different hosts on an on-demand basis is lost.

There are off-the-shelf solutions for simulating USB devices, printers, and license dongles across Ethernet, but you will have to test the required drivers and network connected devices in your environment. Industrial networks are a bigger problem. Any Ethernet TCP/IP based protocol will probably work in the VM environment, but industrial networks that require proprietary network cards and non-10/100/1000 MB Ethernet cabling will probably not work in a VM. Fortunately, many Ethernet-to-industrial network convertors are available. For example, Ethernet-to-Modus devices allow 30-year-old Modbus connectivity to VMs. The newer OPC protocols (OPC-UA and OPC.Net) are Ethernet compatible and usable in the VM environment. OPC-UA is suitable for tag-based data and complex data, and OPC.Net is suitable for tag-based data. While there may be some concern about the use of Ethernet because of the nondeterministic nature of the protocol, the availability of 1000 MB (gigabit) networks has essentially eliminated this as a valid concern.

Push for vendor support

Dennis Brandl discusses insights on engineering and manufacturing IT integration for Control Engineering.

The final major issue is vendor support. Check with your vendors to understand their support policies for virtualization. Many have some support but may require that you run unvirtualized if a problem develops that they need to duplicate. However, once you move to virtualization, backing out for troubleshooting may be impossible. The little secret that many vendors have is that most are using virtualization in their own development and test environment. Apply pressure to your vendors to support virtualization. It is a technology and solution that is good for manufacturing and helps us apply IT solutions to more industrial problems.

Dennis Brandl is president of BR+L Consulting in Cary, NC, www.brlconsulting.com. His firm focuses on manufacturing IT. Contact him at dbrandl@brlconsulting.com.

- Edited by Mark T. Hoske, Control Engineering, www.controleng.com.

For more on the following topics, click on the links below the descriptions.

  • Engineering and IT Insight: Virtualize manufacturing IT - Virtualization simplifies many manufacturing system problems, such as upgrades, backups, and standby methods.
  • Engineering and IT Insight: Future is virtual for manufacturing IT - Virtualization benefits include faster startup, more computing power, and easier upgrades.


Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me