Engineering and IT Insight: Future is virtual for manufacturing IT

Virtualization benefits include faster startup, more computing power, and easier upgrades.

03/27/2011


I have seen the IT future, and the future is virtual. Future IT environments will be built on virtualized systems, and this will include the multiple IT systems used in manufacturing. This includes databases, historians, HMIs, schedulers, and even controllers that we use to run our manufacturing operations. Today virtual systems have many forms from internet accessed “cloud” based systems to company owned server farms running hypervisor servers. Virtualization benefits for manufacturing IT include faster applications, startup in hours instead of months, more computer power, and easier upgrades.

Virtual systems are an old idea that has been resurrected with modern technology. During the early days of computing, in the 1960’s, there was a concept called TSO (time sharing option) available on IBM’s MVS operating system. It essentially made one IBM mainframe computer look like multiple IBM mainframe computers each linked to a separate terminal, each running one application. The modern equivalent takes this to the next level and makes one server act like multiple servers at the operating system layer. There are multiple methods for virtualization, but the one that will be most common in all future server farm environments will be based on the hypervisor concept. A hypervisor is a stripped down operating system that provides a virtual environment for other operating systems. It masks the underlying hardware by providing a complete virtual hardware environment. The virtual environment provides each virtual machine with a number of core processors, memory, disk space, and network access. The hypervisor runs guest operating systems, such as Microsoft Windows Server 2008, Microsoft Windows 7, Linux, and even Microsoft DOS. The most used hypervisor systems are VMWare’s vSphere (a stripped-down and customized Linux), Citrix’s XenServer (also a stripped-down and customized Linux), and Microsoft’s Hyper-V (a stripped-down and customized MS-Server 2008).

Moore’s Law is the reason that virtualization will become the dominant IT implementation architecture. Moore’s Law is an empirical observation made in1965 that the number of components in integrated circuits that can be placed on a chip doubles every two years. Forty-five years later, most experts believe that we still have several more doubling cycles to go before we reach hard physical limits.

While the speed of processors has started to level off at about 3 GHz due to limitations of heat dispersion and the speed of light, chip manufacturers have instead added core processors to chips. Four, eight, and 16 core processors are common, and future systems will have hundreds of core processors. Memory density has also increased, following Moore’s law, making massive amounts of RAM available for the multicore processors. Disk density and network speeds are also doubling at their own rates, providing terabytes of inexpensive disk storage and Gigabit network access. These advancements mean that a single virtualization server can replace tens of nonvirtualized servers and this will cause a major change in how we build, buy, use, and manage IT services. With so much computing power available in a single server, the old IT concept of one server per main application does not make sense.

Another feature of the hypervisor environment is that it takes only minutes to create a new virtualized server. All of the major hypervisor systems allow you to take a snapshot of an existing system and to use that snapshot to create a new server by copying the snapshot file. The first installation of an operating system takes the normal amount of time, but later installations can be done in minutes. Most virtualized IT departments keep snapshots of multiple operating systems at different patch levels so that they can quickly build any system that an application needs.

The new IT hardware model will be a utility system model, just like the electrical power model and telephone model. In today’s environment it may take weeks or months to order a new server. This includes time to obtain approval, check if there will be space for the server in the server farm, determine the hardware required by the application, order the hardware, install the operating system, and add it to the corporate network. All this must be done before the application is even loaded on the server. Compare this to ordering a new phone line or an additional electrical outlet. The support organization manages the available resources, autonomously adds or deletes hardware to meet needs, and rapidly provides requested services. The modern IT environment will run in a similar manner. The cost of a virtual server (processer, memory, and disk) in a virtualized environment is only a few percent of the cost of an equivalent physical server. Virtual server costs are so low that they will probably be handled as normal expenses and not as capitalized purchases. In the future you will decide on the application needed, obtain the required server specifications from the vendor, order a virtual server from the IT department, and install the software in hours or days instead of months. IT departments will manage the virtual servers, expand the server farm to meet expected needs, and decommission virtual servers (free their resources) when the applications are no longer needed.

Future columns will address the economic drivers that will force most, if not all, manufacturing IT systems into the virtualized environment. These include the actual cost savings in hardware, HVAC, and space that users will see in this environment; how virtualization provides a cost-effective patching strategy; using virtualization in application upgrades; and how virtualization handles backups and standby problems.

- Dennis Brandl is president of BR+L Consulting in Cary, NC, www.brlconsulting.com. His firm focuses on manufacturing IT. Contact him at dbrandl(at)brlconsulting.com. Edited by Mark T. Hoske, Control Engineering, www.controleng.com.


Also see:

www.citrix.com/virtualization

www.microsoft.com/virtualization

www.vmware.com/virtualization

 

7 Bad Habits of Unsuccessful Projects

Control Engineering Manufacturing IT channel

 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me