Engineered Living Spaces—for Mice

Inside the Baylor College of Medicine's Center for Comparative Medicine, the heating, ventilation and air-conditioning (HVAC) system serves a series of rooms filled with cages that house valuable transgenic mice used for research. Due to extensive cost and control engineering, the engineers at Affiliated Engineers, Inc., Madison, Wis.

12/01/2000


Inside the Baylor College of Medicine's Center for Comparative Medicine, the heating, ventilation and air-conditioning (HVAC) system serves a series of rooms filled with cages that house valuable transgenic mice used for research. Due to extensive cost and control engineering, the engineers at Affiliated Engineers, Inc., Madison, Wis., have created an optimal environment for these research subjects.

Each room now houses a number of cage racks, with each rack having a duct system that is directly attached to air-in and air-out connections. Each cage-a clear enclosure about the size of a shoebox-attaches to a ventilation nozzle connected to the rack-duct system.

In engineering the best ventilation system for the cage racks, the engineers explored a number of options, including the possibility of having an integral fan and filter in each rack.

In the end, it was decided that the most efficient solution was to have one mechanically engineered fan/filter system located in the interstitial zone above the ceiling in each room.

According to Christina Durovich, project manager with the Baylor College of Medicine, moving the fan motors for the caging system above the ceiling and animal rooms streamlined maintenance and eliminated the need to expose service personnel to the animals.

In addition, having one fan/filter per room was more cost-efficient than one per rack, and locating the fan and ductwork above the room required less duct usage and design time. The move even improved sanitation by eliminating a possible dust ledge in the room.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me