Engineered for Seniors

Balancing costs with resident well-being presents a challenge for mechanical and electrical engineers

07/01/2001


A visit to a senior-living facility today presents a much different picture from the traditional retirement home of a decade or two ago. Particularly with the development of more continuing-care retirement communities (CCRCs), the trend has been for designers to extend the "residential nature" of each phase of the community for as long as possible—allowing residents to feel as if they are living in their own homes.

Resident comfort plays a critical role, and sometimes something as simple as the ability to regulate one's room temperature or apartment can affect a facility's success. However, while comfort is the most important consideration from a design standpoint, other factors such as budget, population size and project goals make system selection much more difficult.

"You really need to understand the concerns of the client," says David Murray, president of the San Antonio engineering firm Murray & Associates Inc.

"Do they maintain a skilled maintenance staff, or are they unskilled? Can you justify added costs for M/E systems, or is the money better spent on resident programs? It's a tough decision." The cost debate

While the battle between first cost and life-cycle cost did not originate with the development of senior-living facilities, it certainly plays a significant role in terms of how the projects are designed.

"The elder-care community is still largely developer-based, and developers look for returns of three to five years," says David McMullin, P.E., a principal with Gresham, Smith and Partners in Nashville. "It won't be until we move away from the developer mentality that we'll see a change in the way mechanical systems are designed."

Due to budget constraints, the most commonly used HVAC systems in senior facilities are direct-expansion split or through-wall systems. To their advantage, these systems have been developed for residential applications, and provide a sense of familiarity to residents. However, despite the first-cost savings, the systems are expensive to operate and maintain in the long run. They are also noisy—one reason Murray will not use packaged units in Alzheimer care facilities. "Male dementia patients become particularly agitated by the units and at some point start viewing them as urinals," notes Murray.

Another system is the behind-the-wall, ducted system—often tied to an air- or water-source heat pump. A ducted system is beneficial in that it delivers air more quietly and with a more gentle air-distribution pattern, as opposed to the direct blowing experienced with through-wall systems. Energy efficiency is also greater with a heat-pump system than with the through-wall option.

On the downside, however, space limitations in existing facilities can restrict the use of ducted systems, as can the added cost involved in increased ceiling heights in new facilities. In addition, the initial cost—particularly for installing ground-source systems—remains higher.

"A lot of providers can't get over the first cost," says Gary Hartfield, AIA, a project manager for RTKL's Dallas office. "But with the help of utility incentives, the payback is enough to offset debt coverage, and they'll do it." The maintenance issue

Given the choice, most engineers would install a remotely piped chilled-water system. Not only does this system provide the most comfort for residents, but it is also the most energy-efficient of all the options. In addition, having a remote mechanical room means that all maintenance and operation is performed away from the residents, reducing disturbances.

Unfortunately, other factors limit use of this system type. While economical over the life of the system, a central chilled-water plant has the highest first cost of the options discussed—at times accounting for as much as 25 percent of a project's cost. The system is also better suited for campus-style developments like CCRCs—with multiple resident apartments along with a large number of assisted-living facilities and long-term, critical-care patients—rather than smaller-scale projects. But one of the biggest disqualifying factors for this type of system is the sophisticated maintenance it requires.

"A central plant with a water tower on the roof may be the most economical choice from an efficiency standpoint, but if you don't have the people to maintain it properly, the efficiency decreases tremendously," says Steven Ruiz, AIA, Beery, Rio & Associates, Springfield, Va.

"In some cases, it's simply easier to have four or five extra packaged units stored on site," Murray adds. "When one goes out, you take it out for repair and put another one in. In the end, our 'bag of tricks' is pretty limited." Moving forward

What, then, can engineers do to improve system design? At present, select the highest-efficiency and easy-to-maintain systems within the classes of equipment being used.

"We really need things to settle down on the health-care side of the issue," says McMullin of Gresham, Smith and Partners. "If institutions can't predict what they're going to be paid [for medical costs], then they're less likely to commit money to long-term solutions. Yes, they want to minimize the cost of utility consumption, but it's more likely they'll want to minimize the length of time their capital is exposed."

Bigger changes in system design are on the horizon, however, as a result of changes in the resident population, according to RTKL's Hartfield. "The average age of people living in senior facilities is dropping," Hartfield says. "People are moving in at 65, when they're mobile and can play golf. As a result, they're going to be paying living expenses for a longer time, and they're going to have to manage their money. Residents will become more demanding, and systems will have to become more flexible and more efficient."



Flexibility for the Future

One of the reasons senior-living facilities have changed in recent years is because they serve younger consumers. Now critical to the success of these facilities is the ability to offer a variety of programs and services of interest to residents, as well as having the flexibility to change over the years. Consequently, the mechanical and electrical systems that support these services must also have flexibility.

For example, one trend which has been gaining popularity is wiring facilities for Internet access—either through a central computer lab or directly to residents' rooms. Meeting this growing need requires planning on the design side, not just for the additional wiring needed, but also for the additional electrical capacity. And, instead of dial-up service, many facilities are now being equipped with direct subscriber line service, and in some cases, fiber-optic wiring.

"A lot of baby boomers who are retiring want to be able to check their stock portfolio online or communicate with their grandchildren by e-mail," says Gary Hartfield, AIA, of RTKL's Dallas office. "Because residents demand it, administrators are willing to pay the money."

At Bethany Homes in Providence, R.I., flexibility is the underlying theme of a renovation project currently underway. In an attempt to reach out to active seniors in the surrounding community, Bethany's administrators have developed a program where community residents can attend events and classes at the facility—thereby introducing potential residents to the facility and also helping current residents remain active.

To meet this goal, project designer Jonathan Knowles, of Briggs Knowles Architects and Designers in New York City, developed a series of movable wall panels and cabinets for the main activity room. Depending on the activity—a concert or a crafts class—the room can be partitioned to meet changing needs.

Because of the flexible nature of the room, lighting also had to be flexible, and the design team chose special fixtures operating on a swivel to easily allow changes to the lighting scheme.

"Chances are that once programs are developed, the lighting will be set up in the pattern that works best and then remain in that position," Knowles says. "But the point is that they have the ability to change it as needed."

Lighting the Way

When it comes to lighting senior living facilities, two major design factors must be taken into consideration: glare and safety.

"All light sources—natural and artificial—must be looked at as a source of irritation," says David Murray, president of the engineering firm Murray & Associates Inc. of San Antonio. "The complication is that seniors also need more light in order to see effectively. They need more foot-candles."

To diffuse the glare from natural lighting, Murray recommends incorporating overhangs into the physical design of the facility. He also designs a combination of indirect lighting and downlighting that provides visual warmth to a room but keeps light out of the line of vision.

"Fixture choice is important because you want to shade filaments from direct view," Murray says. "And despite the trend to make these facilities more residential than institutional, you want to limit use of decorative fixtures, such as candelabras and chandeliers."

From a safety standpoint, a growing number of facilities are incorporating motion detectors into lighting schemes in residents' rooms.

"You don't want a resident getting up in the middle of the night and not being able to find the light switch," says Steven Ruiz, AIA, of Beery, Rio & Associates of Springfield, Va. "With motion detectors, the lights go on automatically and the resident doesn't risk hurting himself."

Ruiz recommends testing the sensitivity of various models before making a selection, as well as testing various locations before choosing a final placement. "We've had cases where people in the hallway were setting off the sensors and causing the lights to go on," Ruiz says. "That didn't make residents too happy."



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me