Energy-saving lighting specifications for commercial buildings

The Dept. of Energy and the Commercial Building Energy Alliances announced voluntary energy-saving specifications for lighting fixtures and parking lot and parking structure lighting.

02/15/2012


The Dept. of Energy (DOE) has announced new voluntary energy-saving specifications for lighting troffers – rectangular overhead fixtures used in commercial buildings – as well as parking lot and parking structure lighting. The new performance criteria were developed by the DOE's Commercial Building Energy Alliances (CBEAs), which bring together major U.S. companies from a wide range of sectors to identify and implement successful energy efficiency and cost-saving practices. Building operators can voluntarily adopt these specifications for new buildings or building upgrades to reduce their energy bills and carbon emissions.

The potential to reduce the nation’s energy use through better lighting choices is enormous. On average, over half of the lighting fixtures in commercial buildings operate for more than 10 hours a day and collectively consume more than 87 terawatt hours of electricity annually, which is equivalent to the energy used by nearly 3 million homes. These new commercial lighting specifications can reduce energy use by more than 40% compared with conventional lighting and have the potential to save businesses up to $5 billion annually.

The new CBEA High Efficiency Troffer Specification provides minimum performance levels for LED and fluorescent troffers used in commercial buildings, including offices and restaurants. The new specification delivers energy savings of between 15% and 45% compared with conventional systems. The specification also includes an optional section on lighting controls, which can boost savings up to 75% by employing technologies such as motion sensors and timers.

DOE also released updated specifications for high-efficiency parking lot and parking structure lighting. Both public and private organizations are increasingly using systems that meet DOE’s high efficiency parking lot lighting specification. This specification typically reduces energy use by 50% compared with conventional parking lot lighting.

Through the CBEA, the DOE collaborates with building owners, operators, and manufacturers to develop minimum performance requirements that are voluntarily adopted by CBEA members. 

- Edited by Chris Vavra, Consulting-Specifying Engineer, www.csemag.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me