Energy company shifts focus to wind power

Consulting Engineers Group has delved into designing and building wind farms. The move has proven to be not only ecologically friendly, but also economically savvy.

09/15/2008


Farmington, Minn.-based Consulting Engineers Group (CEG)—a subsidiary of Dakota Electric Assn .—provides electrical utilities with design/build services on high-tech transmission and distribution systems. Five years ago, CEG began working in earnest on growing its involvement in the burgeoning wind power market.

According to vice president and senior project engineer Vince Granquist, the move has paid off in no small way.

“It is far and away our biggest area of growth,” said Granquist. “At this point, it is probably over 75% of the company’s focus.”

The new concentration started when Granquist noticed Carleton College, a nearby liberal arts school, had begun plans on a wind turbine. Curious, he started picking the brains of all the people involved in the project; his interest grew, and he moved onto contacting people on other small wind-related projects in his part of the state. Based on the stories Granquist heard and experiences he witnessed, the company decided to jump into wind farms itself.

A key aspect of a wind farm centers on the designing and installation of collection systems, including cable. CEG uses hundreds of thousands of feet of 35 kV underground cable (preferring Hendrix Wire and Cable’s TRXLP) cable to connect turbines to each other and back to the substation. Granquist estimates a typical 100 MW wind farm uses approximately $1 million worth of underground cable, about an eighth of the total electrical-work bill.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me