Embedded PC has Profinet interface

The CX8093 Embedded PC from Beckhoff Automation is equipped with a Profinet interface and is suitable as a stand-alone controller and can be used as a tie-in with larger Profinet systems.

09/13/2013


The CX8093 Embedded PC from Beckhoff Automation is equipped with a Profinet interface and is suitable as a stand-alone controller and can be used as a tie-in with larger Profinet systems. Courtesy: Beckhoff AutomationThe CX8093 Embedded PC from Beckhoff Automation is equipped with a Profinet interface and the option to integrate a virtual device. The DIN rail mounted CX8093 is equipped with a 400 MHz ARM9 CPU for ultra compact PC-based control.

The CX8093 is suitable as a stand-alone controller for a wide range of industrial applications in smaller sized machines or systems and can be used as a tie-in to larger Profinet systems. The CX8093 Embedded PC from Beckhoff is equipped with a Profinet RT device interface designed as a 2-port switch for daisy-chain cabling. A special feature is the added functionality of a virtual device which can be used to double the process data size or to connect a second controller.

When the optional virtual device (slave interface) is activated, the CX8093 Embedded PC behaves like two Profinet devices. Accordingly, the CX8093 can process twice the amount of Profinet process data. The network name of the two devices can be set via the address switch or in software using TwinCAT System Manager from Beckhoff. The IP settings are allocated by the Profinet controller.

A further benefit of the virtual device is the ability to communicate with a second Profinet controller, which is a simple way to increase system availability. On the one hand, the CX8093 (as a local controller) can verify the two incoming master signals by means of a plausibility check to monitor the function of the cabling, for example. On the other hand, failure of one of the masters can be detected and the second master can respond accordingly.

The space-saving CX8093 Embedded PC measures only 65 x 100 x 80 mm. It runs Windows CE 6.0 and features a 400 MHz ARM9 CPU, 64 MB RAM and a MicroSD card with up to 4 GB storage capacity. The range of Beckhoff IP 20-rated I/O, including Bus Terminals and EtherCAT Terminals can be connected directly to the CX8093. During start-up, the CX8093 automatically detects which of these I/O systems is connected. Another special feature is a capacitive 1-second UPS that enables persistent data to be saved in the event of a supply voltage failure. The controller is programmed via TwinCAT PLC automation software.

Beckhoff Automation

www.beckhoff.com 

- See more Control Engineering embedded systems products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me