Embedded control: Zero-drift, programmable instrumentation amplifier with diagnostics

National Semiconductor's LMP8358 simplifies pressure and thermocouple bridge measurements with easy detection of shorts, open circuits and degraded source connections.

04/08/2010


 

National Semiconductor Corp. introduces what it's calling the industry's first zero-drift, programmable instrumentation amplifier with on-chip diagnostics. The LMP8358 simplifies pressure and thermocouple bridge measurements by allowing users to detect shorts, open circuits and degraded source connections in remote industrial applications. This diagnostic capability prevents circuit shutdowns in medical instruments, precision weigh scales, pressure sensors and motor control systems.

National Semiconductor instrumentation circuit
The LMP8358 uses patented techniques to measure and continuously correct its input offset voltage (5 uV typical), eliminating offset drift over time and temperature, as well as the effect of 1/f noise. This leads to a flat noise spectrum of 27 nV/sqrt Hz. The unit's programmable frequency compensation enables programmable bandwidths, and its offset compensation circuit does not introduce distortion and aliasing for signals lower than 12 kHz of bandwidth.

The unit is equipped with electromagnetic interference (EMI) suppression filters to reduce unwanted radio frequency (RF) interference from external sources, such as cell phones or nearby antennas. Additional filtering can be added with one external capacitor. It is built on National's CMOS7-5V process technology and provides an optimized signal path solution for precision systems when combined with the 16-bit ADC161S626 or 14-bit ADC141S626 analog-to-digital converters.

The LMP8358 provides glitch-free transitions between gain settings, which can be programmed to 10, 20, 50, 100, 200, 500 or 1000 through a serial peripheral interface (SPI) or parallel interface. All gain settings have less than 0.1 percent typical gain error. This enables manufacturers to perform system calibration by applying specific signal levels at various gains and temperatures. The unit's gain can be set to an arbitrary value using two external resistors.

Technical features
Supplied in 14-pin SOIC and 14-pin TSSOP packages, the LMP8358 operates from a single 2.7V to 5V supply and operates over a wide temperature range of -40 degrees C to 125 degrees C. The amplifier provides 10 uV maximum offset voltage and 50 nV/C maximum offset voltage drift. It features a gain bandwidth (GBW) of 8 MHz while consuming only 1.7 mA of supply current. A power-conserving shutdown mode reduces current consumption to less than 1 uA. The LMP8358's registers allow designers to program the chip's bandwidth, shutdown and fault detection circuitry. Designers also can "daisy chain" multiple LMP8358 ICs.

The LMP8358's ground-sensing CMOS input provides a high common-mode rejection ratio (CMRR) of 120 dB. It's capable of sensing differential input voltages in a common-mode range that extends from 100 mV below the negative supply to 1.4V below the positive supply. This makes the LMP8358 well-suited for interfacing with ground-referenced sensors, supply-referenced sensor bridges and any other application requiring precision and long-term stability.

To order samples and an evaluation board, visit www.national.com/pf/LM/LMP8358.html
- Edited by Renee Robbins, senior editor
Control Engineering News Desk
More embedded control news and products from Control Engineering



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me