EC: Zlinx Xtreme

Network Integration - wireless - B&B Electronics, Zlinx Xtreme. Eliminating up to 40 miles of wiring for industrial wireless sensor networks (WSNs) in harsh environments, the Zlinx Xtreme IP67 outdoor-rated wireless radio modems and I/O modules offer easy field configuration options to set up reliable and secure P2P and P2MP wireless communications to monitor serial or sensor data. This is a Control Engineering 2011 Engineers' Choice (EC) Honorable Mention.

11/01/2010


Zlinx Xtreme - Eliminating up to 40 miles of wiring for industrial wireless sensor networks (WSNs) in harsh environments, the Zlinx Xtreme IP67 outdoor-rated wireless radio modems and I/O modules The Zlinx Xtreme IP67 outdoor-rated I/O modules and radio modems provide reliable wireless monitoring and control of sensor or serial data in harsh and remote environments. Field configuration options facilitate wireless connections to monitor temperature, pressure, level, flow or other analog or digital I/O. Wirelessly emulating wired technology, the units mount directly to panels, poles, or machines to eliminate cabinets or enclosures and up to 40 miles of wiring. Based on license-free, proprietary RF, the wireless sensor transceiver technology connects dataloggers, controls or supervisory-control- and-data-acquisition (SCADA) equipment with up to 99% of sensors on the market.     The I/O modules provide two analog inputs, two analog outputs, two digital inputs,  and two relay outputs and feature selectable I/O, both digital (PNP/NPN) and analog (0 to 5 or 10 V, 0 to 20 mA, or 4 to 20 mA). Point-to-point/peer-to-peer (P2P) or Modbus configurations are available. In P2P, an auto-configure feature lets users quickly map two units without a PC.

The serial radio modems offer 256-bit AES encrypted radios with low-latency (8 ms) response rates, and can act as Modbus gateways when used with Xtreme I/O modules for P2P or point-to-multipoint/peer-to-multi-peer (P2MP) connectivity. Plug-and-play design lets users quickly configure two identical I/O modules with the push of a button. No additional converters or factory adjustments are needed.    Other features include a fail-safe output state that resets I/O to a user-defined state in the event of communication failure, and, in Modbus modes, exception reporting can send trouble alerts through any connected devices.

Devices are tested to EN61000-6-2 and operate from 40 °C to 74 °C. Radio modems: 2.4 GHz short range - $399; 900 MHz long range - $549; I/O modules:  2.4 GHz short range - $549; 900 MHz long range - $699.

www.bb-elec.com

www.bb-elec.com/Subcategory.asp?SubCategoryId=929&Trail=3&TrailType=Top

B&B Electronics

For more, see www.controleng.com/awards.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me