EC: NI CompactRIO

Machine and Embedded Control - PACs: National Instruments, NI CompactRIO. The new NI cRIO-9025 embedded real-time controller is a new addition to the NI CompactRIO platform that provides a more rugged -40 to 70 C deg extended temperature operating range along with a higher performance processor which makes it ideal for industrial and embedded engineers prototyping and deploying advanced monitoring and control systems. This is a Control Engineering 2011 Engineers' Choice (EC) Award winner.

11/01/2010


NI CompactRIO - The new NI cRIO-9025 embedded real-time controller is a new addition to the NI CompactRIO platform that provides a more rugged -40 to 70 C Â extended temperature operating range along with a higher performance processor which makes it ideal for industrial and embedded engineers prototyping and deploying advanced monitoring and control systems. This is a Control Engineering 2011 Engineers' Choice (EC) nominee.The new NI cRIO-9025 embedded real-time controller is part of the high-performance and reconfigurable NI CompactRIO advanced monitoring and control platform. The controller works with any of the existing CompactRIO reconfigurable chassis, which include field-programmable gate arrays (FPGAs) that are programmed using the NI LabVIEW 2010 graphical system design platform. Using LabVIEW and CompactRIO, engineers quickly can implement custom analog and digital control loops, along with high-speed signal processing algorithms to meet their advanced measurement and control application needs.

The NI cRIO-9025 features an industrial 800 MHz real-time Freescale processor running a VxWorks RTOS for deterministic, reliable real-time applications and contains 512 MB of DDR2 RAM and 4 GB of nonvolatile storage for data storage. The controller also provides dual Ethernet ports for network programming and communication, USB and RS232 ports for removable storage and connection to peripherals and dual power supply 9-35 V dc inputs. The cRIO-9025 controller is programmed with the LabVIEW Real-Time Module, which includes hundreds of built-in functions for signal processing, control, advanced mathematics, simplified interfacing to the reconfigurable FPGA and more. Additionally, LabVIEW provides the ability to take existing C code or text-based models and run them embedded on the NI cRIO-9025 real-time controller.

In addition to an extended operating temperature range, the new CompactRIO controller is available with conformal coating. This coating is a specially formulated thin film material applied directly to circuit boards within the cRIO-9025. It provides an impermeable seal to protect circuitry from humidity, moisture, mold, mildew, fungus, dust and corrosion caused by exposure to extreme environments. Application areas in which conformal coating can provide protection include marine, railway, automotive, factory monitoring, fuel cell testing and oil and gas refining.

www.ni.com

www.ni.com/compactrio

National Instruments

For more, see www.controleng.com/awards.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me