EC: L Series Temperature Controller

Machine and embedded control – PLCs: The L Series Temperature Controller from Mitsubishi Electric is intended to reduce energy consumption and improve manufacturing sustainability. This is a Control Engineering 2012 Engineers’ Choice honorable mention.

11/17/2011


L Series Temperature Controller. The L Series Temperature Controller from Mitsubishi Electric is intended to reduce energy consumption and improve manufacturing sustainability. This is a Control Engineering 2012 Engineers’ Choice finalist.Mitsubishi Electric’s L60TC temperature controller performs PID operation to reach the target temperature based on input from an external temperature sensor. Up to four loops of temperature adjustment control can be performed simultaneously in a single module. In addition, loop control can be performed using analog modules in the system; input from an A/D converter module or output to a D/A converter module can be processed. The module controls temperature by outputting the operation result to a heater or others in transistor output. The L60TC4 performs temperature adjustment control automatically when the user simply sets PID constants necessary for PID operation: proportional band (P), integral time (I), derivative time (D), and temperature set value (SV).

No special instructions are necessary to perform PID control. Using the auto-tuning function or self-tuning function enables the PID constants to be set automatically by the L60TC. Complicated PID operational expressions to determine PID constants are not necessary. Temperatures of multiple loops can be adjusted to simultaneously reach the set value of each; temperatures are controlled evenly without any partial heat exaggeration. Designed to directly improve manufacturing operating costs, the L60TC is the first temperature controller with advanced, integrated features to specifically address a reduction in energy consumption. Synchronous Temperature Rise creates a uniform temperature control through the ability to manage multiple loops, eliminating partial thermal expansion and burn-off. Peak Current Control controls the heater’s current flow without the need to synchronize the output timing. 

www.meau.com

www.meau.com/eprise/main/sites/public/Products/Programmable_Logic_Controllers/L_Series/default

Mitsubishi Electric

Return to the list of the 2012 Engineers' Choice honorable mentions.

View the list of the 2012 Engineers' Choice winners.

View the complete list of the 2012 Engineers' Choice finalists.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me