EC: Fluke 381 Remote Display True-rms Clamp Meter with iFlex

Power - monitoring, protection - Fluke Corporation. Fluke 381 Remote Display True-rms Clamp Meter with iFlex -Clamp meter's detachable display increases convenience and safety; iFlex current probe circles large, tightly-spaced conductors. This is a Control Engineering 2011 Engineers' Choice (EC) Award winner.

11/01/2010


Fluke 381 Remote Display True-rms Clamp Meter with iFlex The Fluke 381 Remote Display True-rms AC/DC Clamp Meter with iFlex is a full-featured clamp meter with an important extra: users can remove the detachable wireless display for even more flexibility, convenience and safety. This means that a single technician can do jobs that used to require two people: clamp the Fluke 381 around a conductor, remove the display, then close the equipment cabinet or move up to 30 feet away to operate controls, all while watching real-time readings.

The Fluke 381 clamp meter can handle 1000 A ac and dc current measurement with fixed jaw and 2500 A ac current measurement with the included iFlex flexible current probe; that much amperage capability is rare in a tool of this price and opens up new possibilities for electricians working up to the service entrance. The Fluke 381 also provides 1000 V ac and dc voltage measurements, true-rms ac voltage and current for accurate measurements on non-linear signals and frequency measurement to 500 Hz with both jaw and iFlex probe. The Fluke 381 clamp meter measures to 60 kΩ resistance measurement with continuity detection and records min, max, average and inrush readings to capture variations automatically.

The new Fluke iFlex current probe i2500-18, included with the Fluke 381 clamp meter, allows users to reach around large or awkward-shaped conductors, while the small 0.3-inch profile allows the coil to reach between tightly-packed cables and improves access in crowded spaces. The iFlex probe connects directly to the meter, displaying current measurements without error-prone scaling factors. In addition to ac current measurement, it also works with frequency, inrush, and min/max/avg functions.

The Fluke 381 meter and iFlex probe are safety rated for use in hazard category IV (CAT IV) 600V environments (CAT IV 600V, CAT III 1000 V).

www.fluke.com

www.fluke.com/Fluke/usen/Electrical-Test-Tools/Clamp-Meters/Fluke-381.htm?PID=70413

Fluke Corporation

For more, see www.controleng.com/awards.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me