EC: Fluke 365 Detachable Jaw True-rms AC/DC Clamp Meter

Hardware - Handheld testing, calibration: Fluke Corporation Fluke 365 Detachable Jaw True-rms AC/DC Clamp Meter - Thin, detachable clamp aids access to PLC wiring and improves visibility when measuring AC or DC current, voltage, resistance and continuity. This is a Control Engineering 2011 Engineers' Choice (EC) Award winner.

11/01/2010


Fluke 365 Detachable Jaw True-rms AC/DC Clamp MeterIn 2008, the Fluke Corporation was the first to introduce a high-accuracy milli-amp clamp meter with a detachable clamp head. With further engineering, Fluke has applied the same patented breakthroughs to the new 365 Clamp Meter for measurement up to 200 amps ac/dc and 600 V ac/dc. The new Fluke 365 Clamp Meter has a thin, small jaw design that makes it easy to get around tightly packed wires, and the current clamp jaw is detachable, adding even more flexibility.

The detachable clamp capability is especially valuable for technicians working in the tight confines of programmable logic control (PLC) panels. In normal situations the jaw is attached to the meter body, but when required it can be removed and clamped to the wire under test. The meter body remains connected to the jaw through a flexible 3 foot lead. The Fluke 365 also provides 6,000-Ohm resistance measurement and continuity detection, standard for cabinet troubleshooting but not necessarily standard to a clamp meter. And, state of the art signal processing ensures accurate, stable readings in the noisy electrical environment of a control cabinet.

Some of the smaller features make a big difference, too. The large, back lit display automatically sets the correct measurement range, so the user doesn't need to change switch positions while taking a measurement. And a built-in flashlight helps illuminate the work location and identify wires.  

The compact Fluke 365 fits in the hand and is designed to be easily used by technicians wearing personal protective equipment (PPE).  The meter is safety rated for use in IEC/EN 61010-1:2001, CAT III 600 V environments.

www.fluke.com

www.fluke.com/fluke/usen/electrical-test-tools/clamp-meters/fluke-365.htm?PID=70409

Fluke Corporation

For more, see www.controleng.com/awards.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me