EC: Belden DataTuff 600V Cat 5e AWM-rated Cable

Network Integration - wire, cable, cordsets, connectors - Belden. Belden DataTuff 600V Cat 5e AWM-rated Cable - Unlike traditional Ethernet cables, Belden's 600V Cat 5e AWM-rated Cables are able to be used reliably in particularly tough EMI environments, i.e., motor control centers and switch gear applications. This is a Control Engineering 2011 Engineers' Choice (EC) Award winner.

11/01/2010


Belden DataTuff 600V Cat 5e AWM-rated CableWith the advance of Ethernet technology now reaching motor control centers (MCCs) and switch gear, the Ethernet cabling component must be especially reliable and robust.  In MCCs, drives could produce enough EMI to interfere with many traditional Ethernet cables.  Moreover, the need to monitor and control these devices may demand that the cable enter the MCC.  As a result, an Ethernet cable with excellent noise immunity and the ability to run on or near listed devices is needed.

Belden's DataTuff Industrial Ethernet Cat 5e 600V Cables provide assured performance and reliability in highly concentrated EMI environments, such as those in listed MCC and switch gear applications.  The AWM rating allows the cables to be used on or within a listed cabinet or machine, as well as in more traditional industrial Ethernet applications.

The DataTuff 4-pair shielded cables offer exceptionally rugged construction to provide superior performance, reliability and noise immunity. They feature an overall shielded design with 24 AWG Bonded-Pair solid bare copper conductors, polyolefin insulation, a 24 AWG stranded tinned copper drain wire, and an industrial-grade oil- and sunlight-resistant PVC jacket. One cable style (Part No. 7958A) has an overall Beldfoil shield to meet the EMI requirements of most plant environments, this cable is MSHA approved.  The other style (Part No. 7957A) has an overall Beldfoil shield + 70% tinned copper braid, making it suitable for use in more extreme EMI environments.  Both cables are Ethernet/IP compliant.      Belden's patented Bonded-Pair construction contributes to the cabling's electrical stability and performance.  In Bonded-Pair cables, the conductor insulations of each of the cable pairs are affixed to each other along their longitudinal axes to maintain conductor concentricity and ensure that no performance-robbing gaps between conductors can occur, before, during and after installation. Belden calls this unique capability Installable Performance.

www.belden.com

Belden

For more, see www.controleng.com/awards.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me