EC: Allen-Bradley GuardLogix 5572S, 5573S PACs

Safety - Machine safety: Allen-Bradley GuardLogix programmable automation controllers are designed to provide OEMs and manufacturers with integrated safety, motion, discrete and drive control capabilities in one controller, while executing SIL2 and SIL3 safety functions. This is a Control Engineering 2013 Engineers' Choice Award winner.

11/12/2012


Allen-Bradley GuardLogix programmable automation controllers are designed to provide OEMs and manufacturers with integrated safety, motion, discrete and drive control capabilities in a single controller, while executing SIL 2 and SIL 3 safety functions. This is a Control Engineering 2013 Engineers' Choice finalist.The Allen-Bradley GuardLogix controller provides the same automation capabilities as the Allen-Bradley ControlLogix platform, plus safety-rated control for safety-related functions up to and including SIL3, PLe CAT IV. With one software program managing safety and standard functionality, engineers no longer need to manually manage the separation of standard and safety memory or worry about partitioning logic to isolate safety. This can also eliminate the need to write and coordinate multiple programs on different controllers, which in turn can reduce training and support costs.

In addition, one development environment helps eliminate expensive redevelopment. For example, if a control engineer needs to scale from one line to three, it’s as simple as porting the necessary application from one to the next. Fewer components also mean smaller panel enclosures, saving money on control cabinets and floor space. The integration of safety and standard control systems also provides operators and maintenance personnel with visibility to all machine events, including safety events, via the human-machine interface.

With the knowledge provided by the integrated system, personnel can respond quickly to return the machine to full production. The controller further benefits from the introduction of the Point Guard I/O SIL3 analog input module designed to provide automation and safety functionality in the Point I/O system. Users can apply the Point Guard I/O analog input module to measure temperature, pressure, and flow rate for analog safety functions.

http://discover.rockwellautomation.com/EN_Safety_Solutions.aspx

http://ab.rockwellautomation.com/programmable-controllers/guardlogix-controllers-with-safety

Rockwell Automation



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me