Ductless split systems

Three wall-mounted ductless split systems offer efficiencies up to 33 SEER.

03/30/2015


Three wall-mounted ductless split systems with efficiencies up to 33-SEER.Fujitsu's wall-mounted ductless split systems provide up to 33 SEER and HSPF of up to 14.2, making the entire line Energy Star Most Efficient. All of the inverter wall-mount systems are available as split system heat pumps, and offer super-quiet operation and nearly full heating capacity down to -5 F ambient and cooling operation down to 14 F. Refrigerant pipe lengths can reach 66 ft between the evaporator coil and the condensing unit. Standard features include wireless remote control, ion deodorizing filters, sleep timer, 24-hour timer, dry mode, 4-way auto louver, and auto mode. Motion sensors note when the room has been vacated. After 20 minutes, the set temperature is increased by 4 F when in cooling mode, and reduced by 8 F when heating. When the room is reoccupied, the ESP returns to the previous operating mode.

Fujitsu

www.fujitsugeneral.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me