Duct and fittings for linesets

The Slimduct lineset-protection cover kit provides the duct and fittings necessary for protecting and aesthetically concealing linesets in a routine central split-system or minisplit air conditioning installation.

03/09/2016


The Slimduct lineset-protection cover kit provides the duct and fittings necessary for protecting and aesthetically concealing linesets in a routine central split-system or minisplit air conditioning installation. Courtesy: RectorSealRectorSeal's Slimduct lineset-protection cover kit provides the duct and fittings necessary for protecting and aesthetically concealing linesets in a routine central split-system or mini-split air conditioning installation. The kit's premium-grade duct and fittings are designed and selected for commercial building and include three couplers, wall inlet, end fitting, 90-degree flat elbow, zip ties, and rustproof SAE 304 stainless steel fastener screws. The duct and fittings accommodate air conditioning industry applications and are suitable for temperatures -80° to 140°F. UV-, weather-, and scratch-resistant, they are constructed of heavy-duty PVC extruded lengths and injection-molded fittings. Slimduct's installation requires no additional brackets, fasteners, or hardware.

RectorSeal

www.rectorseal.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me