Dual compressor centrifugal chillers

York YD model “C” dual compressor centrifugal chillers from Johnson Controls feature Optispeed variable speed drives (VSD) and a large chill capacity.

08/24/2015


York YD model “C” dual compressor centrifugal chillers from Johnson Controls feature Optispeed variable speed drives (VSD) and a large chill capacity. Courtesy: Johnson ControlsYork YD model "C" dual compressor centrifugal chillers from Johnson Controls feature Optispeed variable speed drives (VSD) and a capacity range of 1,500 to 6,000 tons (5,300 to 21,000 kW). The unit-mounted low-voltage and floor-mounted medium-range VSD are designed to optimize the chiller and improve efficiency. At AHRI conditions (460 V/60 Hz), the YD model "C" provides up to 3,000 tons (10,550 kW) of cooling. It uses two York centrifugal compressors operating in parallel on a common set of heat-exchanger shells to obtain large chill capacities. The YD model is designed for retrofit applications, district cooling, hospitals, and higher education facilities.

Johnson Controls

www.johnsoncontrols.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me