Drives optimize energy efficiency, reduce control room, panel space, cooling costs

Up to 68% smaller than previous generation drives, compact D-frame drives from Danfoss VLT Drives are optimized to deliver highly reliable performance in the 125 – 450 HP range while exhausting 90% of the drive-generated heat outside the enclosure via the backchannel.

08/22/2012


Danfoss D-Frame VLT Drives are available in a power range from 125-450 hp (90-315 kW) and up to 68% smaller than previous generation D-Frame drives, new D-Frame drives require significantly less panel or wall space than previous models which were already among the smallest in their class. This reduces installation costs and increases installation flexibility. These drives also leverage back channel cooling to remove 90% of the heat generated by the drive, reducing both up front and ongoing costs and making them an ideal panel building solution.

 

“With ever-increasing demands for improved efficiency and reliability in drive technology, OEMs, panel builders and end users are looking for new technologies that can save energy, reduce costs and help simplify operations in a solution that will provide trouble-free operation for years,” said Greg Reichelt, Product Manager High Power Drives, North America. “The new D-Frame VLT drives deliver on each count. Not only are these drives among the smallest in their class, they also include an array of efficiency and safety enhancing options as standard features, enabling customers and end users to reduce both initial and ongoing operating costs.”

 

The new drives are available with IP20, IP21 (NEMA 1) or IP 54 (NEMA 12) enclosure protection ratings. For robust protection they also come standard with conformal coated printed circuit boards, which together with the optional heat sink access panel, help to extend drive lifetime and reliability. The new units can be factory-fitted with optional semiconductor fuses to further reduce installation costs. Additional factory-fitted basic input options, such as mains disconnect, contactor and circuit breaker, eliminate the need to install these basic options externally.

 

New D-Frame drives also use Danfoss’ unique and innovative back-channel cooling concept to keep electronics safely within optimal operation temperatures. The big advantage of back-channel cooling is that system installation and operating costs can be dramatically reduced.

 

“Using a ducted back-channel, air is allowed to pass over the unit’s heat sink with minimal air passing through the electronics area. This way 90% of the heat generated by the drive is exhausted directly outside of the enclosure, improving reliability and prolonging the lifetime of the unit. An IP54 (NEMA 12) seal between the back- channel cooling duct and the electronics area of the VLT drive helps to significantly reduce temperature rise and contamination of the electronic components,” explained Reichelt.

Danfoss provides energy-efficient solutions that help save energy and meet the challenge of climate change. Key competencies are cooling of food, air conditioning, control of electrical motors and heating in buildings – as well as solutions for renewable energy such as solar power. Danfoss also comprises Sauer-Danfoss that is among the world’s leading manufacturers of mobile hydraulics. The 77 year company employs 26,000 employees globally and has 140 sales companies globally.

www.danfossdrives.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me