Drive actively eliminates harmonic disturbances

Like industrial strength noise-cancelling headphones, Danfoss drive quiets the supply grid.

10/07/2009


New VLT Low Harmonic drives from Danfoss address current distortion by performing real-time analysis and actively imposing currents, as needed, to ensure the highest quality sine waves possible from the power supply grid. VLT Low Harmonic drives are appropriate for installations that are generator-powered, or that have generator back-up power, soft power grids, or grids with limited excess power capacity.

Danfoss Drives
Danfoss Drives' VLT Low Harmonic Drive addresses current distortion by performing real time analysis and actively imposing currents to ensure high quality sine waves from the power supply grid.

"In essence, the filter portion of VLT Low Harmonic drives has the same working principle as a set of noise cancelling headphones, where the noise or distortion is measured and a computer phase signal is imposed to compensate for that noise," explains Gregers Geilager, product manager. "As a matter of scale, noise cancelling headphones can inject 100 mW at 50 - 1000 Hz, where VLT Low Harmonic drives can inject several hundred watts at 250 - 2000 Hz,"Geilager says that although only one out of eight motors currently is operated by a frequency converter, the increased use of ever more powerful frequency converters means the need to prevent harmonic disturbances is growing significantly.

"It's expected that the huge potential for energy savings by employing frequency converters will increase the number of drives in use-and hence the potential harmonic disturbance on the supply grid, and the need for smarter harmonic mitigation solutions," Geilager says.

VLT Low Harmonic drives cause no increased winding stress and have no impact on bearing life, says Geilager. "They provide the user with a full readout of the unit performance towards the grid, including a graphical overview of grid behavior. Where the performance of other low harmonic technologies depend on the stability of the grid and load or affect the controlled motor, these drives continuously regulate the network and load conditions without affecting the connected motor. In fact, VLT Low Harmonic drives are motor friendly, with output impulse and shaft voltages compatible with motors conforming to IEC 60034-17/25 & NEMA-MG1-1998 part 31.4.4.2, as per standard VLT drives," he says.

A unique design uses a ducted back channel to pass cooling air over heat sinks with minimal air passing through the electronics area. This allows 85% of the heat losses to be exhausted directly outside of the enclosure, says Geilager. There is an IP 54 seal between the back-channel cooling duct and the electronics area of the low harmonic drive.

VLT Low Harmonic drives share the same modular technology platform as Danfoss' VLT High Power drives and share many of the same features, such as high energy efficiency, backchannel cooling, and user-friendly operation. The modular design means most elements are cost-effectively produced in large scale, enabling individually configured units to be highly customized but available at the price of a mass produced unit, says Geilager.

- Edited by Renee Robbins, senior editor
Control Engineering News Desk
Machine Control, Motion Control news from Control Engineering





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me