Directional airflow panel

Tate's Directional Perf directs airflow from the raised flow plenum to data center racks where cooling is needed.

09/04/2012


Tate's Directional Perf directs airflow from the raised flow plenum to data center racks where cooling is needed. Courtesy: Tate Inc.Tate’s Directional Perf, a perforated directional airflow panel, helps direct airflow from the raised floor plenum to the data center racks where cooling is required. Directional Perf delivers airflow to standard server racks at an angle, increasing the rate of total air capture (TAC) and helping eliminate bypass air, which saves operating expenses and reduces capital expenditures on cooling equipment in new facilities. The perforated panels feature a 25% open area. The panel can also be used as an alternative to aisle containment. To eliminate bypass airflow and mixing of airstreams, 93% of the airflow supplied through the Directional Perf panel is delivered directly to the face of the rack. Unlike other airflow panels that deliver airflow in a vertical plume from the floor, the Directional Perf provides effective containment, thereby reducing the need for rigid containment structures.

Tate Inc.

www.tateinc.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me