DIN-rail mounted surge protection protects control panels

The Varitector VSPC surge protection from Weidmuller is designed to protect control panel equipment from damage and breakdowns causes by local lightning strikes.

12/14/2011


The Varitector VSPC surge protection is designed to protect control panel equipment from damage and breakdowns causes by local lightning strikes. Courtesy: WeidmullerWeidmuller's DIN-rail mounted Varitector VSPC surge protection is a streamlined solution to protect control panel equipment from damage and breakdowns due to local lightning strikes. It is a means to effectively manage the protection of signal circuits in Control and Instrumentation applications.

Weidmuller’s Varitector VSPC includes over 60 models with a robust range of pluggable, replaceable, single- and multi-channel modular surge protection devices (SPDs). Meeting UL 497B requirements, VSPC provides a combination of wire-to-ground and wire-to-wire protection. The separate bases accommodate field connections and make a ground path from the SPD, via the (grounded) DIN-rail.

Targeted at measurement, control, and fieldbus applications, typically in Water and Waste sectors, VSPC is rated for discharge currents up to 20kA (8/20μs). A combination of gas discharge tubes, varistors and suppression diodes, in single- or multi-stage configurations are used to protect nominal voltages between 5 V dc and 230 V ac. VSPCs are suitable for analog current and voltage loops, dc and ac status signals, and a wide variety of serial interface and telephone network installations. To minimize panel rail space, various VPSC models with four conductors (e.g. two analog loops) can be protected by one 17.8mm (0.7inch) wide module.

The key to ensuring full, continued protection is the VSPC status monitoring option, which shows when the SPD module replacement is needed. The arrestor condition status is displayed on the device via a green/red indicator. An optional remote display is available via a separate VSPC Control Unit, where up to ten SPD modules may be connected. Other features include colored product marking to easily identify different working voltages between a group of modules mounted together on the rail, models for protecting floating signals, and a portable test accessory (V-TEST).

www.weidmuller.com 

Weidmuller

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me