Digital refrigeration compressor

Emerson Climate Technologies Inc.’s Copeland Scroll K5 Digital compressor is designed for low- and medium-temperature refrigeration and has 10% to 100% capacity modulation for precise temperature and pressure control.

03/21/2014


Emerson Climate Technologies Inc.’s Copeland Scroll K5 Digital compressor is designed for low-and medium-temperature refrigeration and has 10 to 100% capacity modulation for precise temperature and pressure control. Courtesy: Emerson Climate TechnologiesEmerson Climate Technologies Inc.’s Copeland Scroll K5 Digital compressor is designed for low-and medium-temperature refrigeration and allows customers added flexibility for new applications (7.5 to 15 hp). The K5 Digital Refrigeration compressor incorporates a variety of features including 10% to 100% capacity modulation, which allows for precise temperature and pressure control. Its vapor injection capability increases system capacity by 50% and efficiency by 20% on average at low temperature rating condition. Its CoreSense Diagnostics monitor capabilities and maintenance cost savings. It is approved for use with R-404A, R-407A/C/F, R134a, and R-22 refrigerants and can be used for both stand-alone and parallel systems. 

Emerson Climate Technologies Inc. 

www.emersonclimate.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me