Differential pressure measurement via industrial Ethernet module

Beckhoff Automation's EP3744 EtherCAT Box is an IP67-rated machine-mountable solution for differential pressure measurement that has six digital inputs and two digital outputs.

10/02/2013


Beckhoff Automation's EP3744 EtherCAT Box is an IP67-rated machine-mountable solution for differential pressure measurement that has six digital inputs and two digital outputs. Courtesy: Beckhoff AutomationBeckhoff Automation's EP3744 EtherCAT Box is a compact, machine-mountable solution for differential pressure measurement. This IP 67-rated module combines compressed air measurement, EtherCAT connectivity, and digital I/Os for use directly in the process, outside of electrical cabinets.

In addition to six digital inputs and two digital outputs, the EP3744 has four pressure inputs with integrated 6 mm fittings. The pressure is measured as the difference to the fifth pressure connection, which is fed via a hose into a protective housing for IP 67 conformity. The measured data is provided in the form of 16-bit values which are transmitted in an electrically isolated manner to the controller. The measuring range is 0 to 1 bar (15 psi), with a resolution of 1 mbar per digit. Further advantages of this system-integrated solution are the short reaction times – due to local measurement using only one A/D converter – as well as the EtherCAT connection and additional digital I/Os, making integration into the control system particularly efficient.

Beckhoff Automation

www.beckhoff.com 

- See more Control Engineering I/O system and module products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me