Diesel generator set

Rated at 1,750 kW, 60 Hz for standby applications, the Cat 3512C diesel generator set features an optimally sized engine and a reduced overall footprint.

04/13/2017


Caterpillar 3512C Diesel Generator SetRated at 1,750 kW, 60 Hz for standby applications, the Cat 3512C diesel generator set features an optimally sized engine and a reduced overall footprint. The generator set provides reliable power that can deliver lower installed costs per electrical kilowatt, reduced fuel consumption, and lower emissions. The Cat 3512C generator set has a footprint of 151.56 sqft, saving up to 13% of installed space and a weight of 31,240 lb, which cuts up to 6% of necessary weight-supporting installation costs. Users may select the standard 108°F ambient radiator or an optional high-ambient radiator that delivers full power with no derating at ambient temperatures up to 122°F.

Caterpillar Inc., www.cat.com/powergeneration

This product is a Finalist in the Consulting-Specifying Engineer 2017 Product of the Year program. View more Finalists and cast your vote at www.csemag.com/votepoy (voting closes June 30, 2017).



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me