dc power distribution recommended practices

Use these three tips to ensure a direct current (dc) power distribution project is successful.

06/16/2014


1. Plan projects to include evaluation of alternatives, including dc systems. Opportunities may include the use of bulk rectifiers and dc buses for cooling fan and pump motors. Additionally, consider the dc voltage used by server equipment and providing a dc buses in the server aisle to feed this equipment. Connection of photovoltaic systems also typically includes a dc interface at less than 600 V.

2. Model the utility, generator, power converters, and loads to help develop interface standards, predict efficiency, validate the concept of operations, and identify key performance constraints, such as stability or harmonic distortion. Models can be used for energy management software development and testing. Many applications are suitable for this type of analysis.

3. Identify the power system equipment electrical interfaces, including harmonics, stability, and voltage requirements. Develop power distribution system architecture and interface standards appropriate for the project.


Jonathan Sauer is an electrical engineer at Jacobs Engineering. He works in the global building design group where he performs electrical systems engineering for buildings and mission critical data centers. Areas of expertise include facility electrical power, backup generation, UPS, automation, networks, commutations, security, fire, lighting, and HVAC.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me