dc power distribution recommended practices

Use these three tips to ensure a direct current (dc) power distribution project is successful.

06/16/2014


1. Plan projects to include evaluation of alternatives, including dc systems. Opportunities may include the use of bulk rectifiers and dc buses for cooling fan and pump motors. Additionally, consider the dc voltage used by server equipment and providing a dc buses in the server aisle to feed this equipment. Connection of photovoltaic systems also typically includes a dc interface at less than 600 V.

2. Model the utility, generator, power converters, and loads to help develop interface standards, predict efficiency, validate the concept of operations, and identify key performance constraints, such as stability or harmonic distortion. Models can be used for energy management software development and testing. Many applications are suitable for this type of analysis.

3. Identify the power system equipment electrical interfaces, including harmonics, stability, and voltage requirements. Develop power distribution system architecture and interface standards appropriate for the project.


Jonathan Sauer is an electrical engineer at Jacobs Engineering. He works in the global building design group where he performs electrical systems engineering for buildings and mission critical data centers. Areas of expertise include facility electrical power, backup generation, UPS, automation, networks, commutations, security, fire, lighting, and HVAC.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me