DC electric motors with potentiometer offer power, control for incubator rotating mechanism

Bosch “VMC” DC electric motor with potentiometer features space-saving compact design, weighs approximately 0.12 kg, allows for easy installation into cabinet-style egg incubators, other industrial systems, and equipment.

03/23/2011


Hens layBosch VMC Motor the eggs, but each year in the U.S. poultry industry, billions of baby chicks are hatched from those eggs by means of electric-powered egg incubators. To power the incubator’s rotating mechanism, which is essential to the development of healthy hatchlings, the Bosch i-Business Group offers the Bosch “VMC” dc electric motor with potentiometer. This 24-volt, 0.22-watt adjustment motor, which also offers design advantages for many different kinds of industrial applications, is one of several different 12V – 24 V dc electric motors with gear boxes that are featured in the Bosch VMC motor family.

The Bosch “VMC” dc electric motor with potentiometer features a space-saving compact design and weighs approximately 0.12 kg, allowing for easy installation into cabinet-style egg incubators and other industrial systems and equipment. The potentiometer, which is included with this model of Bosch VMC motor, is vital for incubator applications because it triggers the on/off electrical circuit for the incubator’s timed rotating mechanism.

Hatching eggs (fertile eggs) are rotated in large incubators to mimic the manner by which chickens and other fowl naturally, and frequently, turn over their “laid” eggs during that period when they sit on them (thereby incubating the eggs) and wait for their chicks to hatch. Hatching eggs must be rotated a few times throughout the day to ensure that the embryos do not stick to the interior walls of the eggs; otherwise the embryos will fail to develop.

Kenn Langosch, Sales Manager for Industrial Motors for Bosch, says, “Having dependable incubators is extremely important to the overall success of the poultry industry. The Bosch i-Business team can help the developers of incubators and other types of farm equipment ensure the reliability of their products by matching Bosch dc electric motors to their critical product design needs.”

The key design characteristics of the Bosch VMC motor with potentiometer include:

  • Nominal voltage: 24 V
  • Nominal power: 0.22 W
  • Nominal current: ≤ 55 mA
  • Maximum current: 250 mA
  • Nominal speed: 6 min-1
  • Rated torque: 40 Ncm
  • Breakaway torque: ≥ 100 Ncm
  • Reduction: 405 : 1
  • Direction of rotation: L/R (direction of rotation can be inverted by changing over +/-)
  • Shaft load max. axial: ≤ 30 N
  • Shaft load max. radial: ≤ 50 N

Bosch Industrial Motors

www.boschusa.com

Bosch

- Edited by Gust Gianos, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me