Data center security and monitoring system

NetBotz 250 is designed to monitor critical IT assets in real-time for protection against physical threats, environmental risks, or human error.

11/18/2016


NetBotz 250 is designed to monitor critical IT assets in real-time for protection against physical threats, environmental risks, or human error. Courtesy of: Schneider ElectricNetBotz 250 is designed for simplified data center security and can be used for IT deployments of varying applications. This scalable environmental monitoring appliance monitors critical IT assets in real-time for protection against physical threats, environmental risks, or human error. The user experience is designed to offer native support for NetBotz connected wireless temperature and humidity sensors for deployment while supporting additional wired sensors, such as spot fluid, vibration, and smoke detection. These capabilities enable immediate detection of common environmental hazards to prevent outages and allow rapid response action. NetBotz 250 is compatible with APC racks and StruxureWare Data Center Expert. The integration with StruxureWare Data Center Expert provides centralized monitoring and management of connected devices and the physical infrastructure. The rack access control functionality restricts rack access to only credentialed users. Configured alerts and outputs, such as beacon alarms, can be set up to notify IT staff in the event of a breach.

Schneider Electric

www.schneider-electric.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me