Critical Power Hospital Electrical Systems: AIA CES accredited online course

CFE EDU is an interactive online platform that offers multi-media educational courses on engineering topics that are critical to your work. Courses are AIA CES accredited and are self-paced for your convenience.

03/01/2017


Critical Power Hospital Electrical Systems: AIA CES accredited online courseCritical Power: Hospital Electrical Systems 
One (1) AIA CES accredited LU and 1 HSW credit available for attendees

Learning Objectives:

  • Assess the unique electrical system requirements of hospitals including those for patient care and non-patient areas.

  • Analyze and compare the differences between emergency and essential power, connected load and demand load, the branches of the emergency power supply system (EPSS), and the types of equipment associated with each branch.

  • Outline backup, standby, and emergency power systems for hospitals versus other building types.

  • Highlight recommended best practices such as ASHE Handbook for Electrical Systems and IEEE White Book.

Technical Experts:

  • Danna Jensen, PE, LEED AP BD+C
    Vice President, Electrical Engineer
    WSP + ccrd, Dallas

  • Robert R. Jones Jr., PE, LEED AP
    Associate Director of Electrical
    JBA Consulting Engineers, Las Vegas

Click here to register for Critical Power: Hospital Electrical Systems



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me